1.0 INTRODUCTION

1.1 Introduction
The #KPV is certified for use as a horizontal termination cap only for
use with the ALP-36S, CLW-40, CLW-50, CLW-72, and SFD-36 direct
vent fireplaces.
Control system configurations:
The battery-backup feature cannot be used with #KPV
The wired wall switch feature cannot be used with #KPV
An appliance with #KPV installed cannot be operated with
battery back-up or a wired wall switch
The #KPV operates on 120VAC, 60Hz electrical service which is
supplied at the fireplace junction box. The current draw of this device
is 0.85 amperes.
The following vent pipe manufacturers are approved for use with
the Kozy Power Vent:
American Metal Products (Ameri-Vent), BDM,
ICC, Metal Fab, Olympia Chimney Supply, Inc., Selkirk, and Simpson
DuraVent.
IMPORTANT OPERATIONAL NOTE: When the control being used to run
the fireplace is activated, there will be up to a 120 second delay before
pilot ignition will begin. This is to allow a pre-ignition purge by the
#KPV. If after 135 seconds the pilot and burner do not light, refer to
Section 6.0 on page 22 of this manual. There will be also 120 second
post-operation purge in which #KPV will continue to run after the
appliance is turned off.
NOTE: The fan motors present in this power vent will generate sound
during operation. The effects of the increased sound level can be
minimized with careful planning during installation of the system.

1.2 Components and Service Parts List

1.2.1 Service Parts List
Replacement Parts can be obtained from your local dealer. Repair of
the #KPV should only be done by a qualified service technician.
#KPV-101
Fan Assembly
#KPV-102
Vacuum Switch
#KPV-103
Vacuum Tube
#KPV-104
Cover Assembly
#700-358
Power Vent IFC Wire Harness
1.2.2 Power Vent Wire Harness - Required
The wire harness connecting the #KPV to the appliance is sold
separately. The length of the wire harness needed varies by

installation.

10' pv wire harness
20' pv wire harness
40' pv wire harness
60' pv wire harness
80' pv wire harness
100' pv wire harness
1.2.3 Optional Components
Power Vent Finishing Extension Kit: #KPV-FEK
Kozy Power Vent #KPV R.5
1.3 Installation
1.3.1 Installation Precautions
This device must be installed by a qualified installer in
accordance with these instructions.
Safety inspection of the venting system should be performed
before and after installation of this power vent. Installation of
the Kozy Power Vent must comply with local, regional, provincial,
state, and national codes and regulations.
DO NOT INSTALL DAMAGED EQUIPMENT OR VENT COMPONENTS
Disconnect electrical power supply before making wiring
connections.
Venting of more than one appliance in a common vent system is
prohibited.
Clearances between the vent pipe and combustible materials
must be maintained.
WARNING: Failure to install, operate, and maintain the power
venting system in accordance with manufacturer's instructions
will result in conditions which may produce bodily injury and/or
property damage.
1.3.2 Installation Guidelines
The exit termination of mechanical draft systems shall not be less
than seven feet above grade when located adjacent to public
walkways.
A mechanical drafting venting system shall terminate at least
three feet above any forced air inlet located within 10 feet.
1.3.3 Painting Requirements
The #KPV may be painted to a desired color. The paint selected must
have sufficient temperature and environmental ratings as described
below.
Prior to painting the #KPV cover assembly, sand the existing
coating with sandpaper or steel wool.
The front of the cap cover assembly may be field-painted and
cured up to 400 degrees Fahrenheit (204° C). All remaining parts
of the cap may be painted, but they may not be cured beyond
190°F (88°C) due to gaskets and components overheating.
Certain areas of the cap surface may reach up to 600° F (316°C).
Paints selected should have sufficient temperature ratings.
Cap cover assembly contains silicone sealant which could
affect adherence of paint. Please advise local painter of silicone
content.
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
INTRODUCTION 3