1.3 Wiring

Fan and motor specifications are provided on the fan's type plate. All the single-phased models are adjustable.
Wires are to be connected as per the wiring diagram. For further details, please see guidelines for the exodraft control
units. All exodraft fans require extra safe-guards in accordance with power current regulations.
Any lightning conductor connected to the fan must respect current applicable legislation.
exodraft motor
Z2
U1
Z1
U2
Isolation switch:
In accordance with the provisions of the EU Machinery Directive* a combustion-gas fan
must always have an isolation switch fitted. The isolation switch must comply with national wiring standards.
*Please refer to Machine Directive (2006/42/EF/-EEC/-EWG/-CEE) – Appendix 1item 1.6.3 "Separation of the sources of energy
The isolation switch must be ordered separately, as it is not part of the standard exodraft chimney fan delivery.
Connecting cable
and wiring
RSV009-4-1
brown = L
RSV160-4-1
blue = Nreg.
yellow/green =
RSV012-4-1
brown = L
RSV014-4-1
blue = Nreg.
RSV016-4-1
yellow/green =
RSV200-4-1
RSV250-4-1
RSV315-4-1
RSV400-4-1
RSV250-4-3
brown = L1
RSV315-4-3
blue = L2
RSV400-4-3
black = L3
yellow/green =
RSV400-4-2
1 – L1
RSV450-4-2
2 – L2
3 – L3
4 + 5 Thermocal switch
yellow/green=
N
Nreg
T2
T1
L
Variable adjust-
able electronic
regulator
Yes
Yes
No
Yes, by frequency
converter max.
60Hz
3000113 RSV DK DE NO SE UK NL FR 120515
Grundfos motor
AUX
MAIN
7
6
8
5
4
Protection
The motor can be
blocked.
(impedance-pro-
tected)
The motor requires
overload
protection
3
2
1
L1
N
3 x 0,75
YEGN
POWER SUPPLY
1 x 230V ~ 50Hz