Westermo TD-32/485 Manuel D'installation page 30

Table des Matières

Publicité

\S Affiche la configuration Active
Cette commande affiche la liste des paramètres de la configuration active.
Par exemple :
AT\S
CMD DESCRIPTION / OPTION
COUNTRY.........SWE
DTE BPS........9600
DTE PARITY....8NONE
LINE SPEED.....NONE
B
BELL MODE.......OFF
E
CMD ECHO.........ON
F
LINE MODE......AUTO
L
SPKR VOLUME.....LOW
M
SPKR CONTROL...CALL
N
AUTO MODE........ON
Q
QUIET...........OFF
V
RESULT FORM....LONG
W
EC MSG............0
X
EXT RESULTS.......4
Y
LONG SPACE DISC..NO
%C
COMPRESSION....BOTH
-K
EXT. SERVICES.....0
OK
Se référer aussi à AT\V
30
Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
CMD DESCRIPTION / OPTION
&A
CHR ABORT OPT....NO
&B
DTR DIAL OPTION..NO
&C
DCD OPTION.......ON
&D
DTR OPTION........0
&G
GUARD TONE.....NONE
&K
FLOW CONTROL....RTS
&L
NETWORK........PSTN
&Q
ASYNC/SYNC........5
&R
RTS/CTS........AUTO
&S
DSR OPT...........0
&T
ENABLE RDL.......NO
&X
SYNC CLOCK......INT
&Y
PROFILE.......NVM.0
\A
MAX BLK SIZE....192
\G
REMOTE FLOW.....OFF
\K
BRK OPT...........5
\N
ECL MODE.......AUTO
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles
CMD DESCRIPTION / OPTION
*H
NEG. SPEED.....HIGH
S0
RINGS TO ANS....002
S1
RING COUNT......000
S2
<ESC> CHAR......043
S3
<CR> CHAR.......013
S4
<LF> CHAR.......010
S5
<BS> CHAR.......008
S7
CONNECT TIME....050
S8
PAUSE TIME......002
S12 ESC GUARD TIME..050
S30 CONNECT INACT...000
S32 XON CHAR........017
S33 XOFF CHAR.......019
S36 FALLBACK ACTION.007
S37 MODE SELECT.....000
S48 V42 NEG CTRL....007
S95 RES. CODE.......000
6178-2491

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Td-32

Table des Matières