Studer xtender xth3000-12 Mode D'emploi
Studer xtender xth3000-12 Mode D'emploi

Studer xtender xth3000-12 Mode D'emploi

Masquer les pouces Voir aussi pour xtender xth3000-12:

Publicité

Liens rapides

quick guide
xtender xth
swiss made power

Publicité

loading

Sommaire des Matières pour Studer xtender xth3000-12

  • Page 1 quick guide xtender xth swiss made power...
  • Page 2 5 ans et est éligible à une extension 5+5. designed and assembled Herzlichen Glückwunsch ! by studer in Switzerland Wir freuen uns, dass Sie sich für eines High-Tech-Gerät entschieden haben, welches bei der Energie-management Ihrer Anlage entscheidende Rolle spielen wird.
  • Page 3 Studer disclaims all responsibility and liability for damage, costs or losses resulting from an installation that does not comply with the instructions, a faulty operation or inadequate maintenance. The use of studer equipment is in any case under the responsibility of the customer.
  • Page 4 Mounting and installation Storage and content Fixing and dimensions 160mm 60°C 220mm -20°C min. 200mm min. 200mm Mounting place min. 200mm The batteries should only be installed by qualified personnel. 34 - 46kg 300mm 230mm...
  • Page 5 Wiring L1 L2 L3 Jumpers Battery connection AC out connection Auxiliary Contacts BAT+, M8 BAT-, M8 AUX1 • 3x10mm cable, 1.6Nm • 95mm cable M8, 10Nm xth 8000-48 xth 5000-24 xth 3000-12 AUX2 • 3x25mm cable, 1.6Nm (xth 8000) NC C NO •...
  • Page 6 Multi units and power up Display Up to 9 Xtenders in the same communication bus Display system on – AC out present 230V / 120V ac blink – standby, load search on – AC in source present blink – AC input current limit is reached Blinking indicator AC out 1x Load search...
  • Page 7 Configuring the xtender Multi units rcc 02/03 3 phase and parallel combination xtender xtender setting con guration assistant L1 1 0 Vac 231 Vac 0 Aac 0.03 kW L1 L2 L3 27.7 Vdc -2 Adc Displaying Configurating parameters real time user Basic settings information Battery management and cycle...
  • Page 8 Technical data Maintenance and recycling Maintenance and recycling Except for the periodic check of the connections (tightening, general IP 20 condition), the xtender does not require any particular maintenance. To dispose of this product, please use the service for the collection Protection Class I of electrical waste and observe all obligations in force in the place of purchase.
  • Page 9 Serial Number : Installed by : Date : Signature : Call our specialists +41 27 205 60 80 or visit studer-innotec.com/support Studer Innotec SA rue des Casernes 57 1950 Sion, Switzerland info@studer-innotec.com 4O92 © All rights reserved Studer Innnotec SA – V1.0...