DROP CEILING INSTALLATION
NOTE: Drop ceiling installations are similar to new construction
installations, except the hanger bars are attached to the T-bars of a drop
ceiling grid, instead of ceiling joists, as described below.
T-BAR INSTALLATION (Fig. 12)
1. Install a ceiling tile onto the T-bar grid at the installation location. Using the
provided template and a keyhole saw make a hole at the desired location in
the ceiling tile.
2. Place the plaster frame/hanger bar assembly onto the ceiling tile into the
newly created hole, making sure the bottom of the plaster frame feeds
through the hole. Adjust the width of both hanger bars to the distance
between the two T-bars, aligning each mounting clip with the top of its
corresponding T-bar. Press down on all mounting clips until they snap onto
the T-bar.
NOTE: Holes are provided on the mounting clips that can be
used to secure the hanger bars to the T-bar. Parts (I.e. screws, hex nuts)
can be purchased separately for this purpose.
Hanger
bar
T-bar
Fig. 12
3. Proceed to Step 3 of the "CEILING JOIST INSTALLATION" section.
ELECTRICAL CONNECTIONS (Fig. 13 & 14)
1. Open the junction box's door by pulling on its metal tab.
2. Break off one of the round knockouts from the junction box using a
screwdriver.
Secure an appropriately sized BX or NM (Romex) cable
connector to the knockout opening. Feed the BX or NM (Romex) cable
through the connector, providing 3" (7,6 cm) of slack inside the junction
box. Tighten the connector to secure the cable in place.
3. Remove at least 3" (7,6 cm) of the cable's outer sheath and remove the
plastic or paper over-wrap. Strip approximately 3/8" (1,0 cm) of insulation
from the ends of all supply wires. Using wire nuts, make the following wire
connections:
WHITE SUPPLY WIRE (NEUTRAL)
BLACK SUPPLY WIRE (HOT)
GREEN/BARE SUPPLY WIRE (GRND)
Be sure that there are no loose strands or loose wires.
4. Wrap all wire connections with electrical tape for a more secure
connection.
NOTE: If you have electrical questions, consult your
local electrical code for approved grounding methods.
5. Carefully stuff all wires and wire connections into the junction box. Close
the junction box's door.
Metal tab
Junction
box
door
Knockout
Housing
Fig. 13
Housing
Wire
nut
Plaster
Mounting
frame
clip
Ceiling
Hole
tile
TO
WHITE FIXTURE WIRE
TO
BLACK FIXTURE WIRE
TO
GREEN FIXTURE WIRE
BX
Cable
BX Cable
connector
Fig. 14
ALL RIGHTS RESERVED. COPYRIGHT  COMMERCIAL ELECTRIC 2011
NOTE: In additional to the main supply cable entering the junction box, one
more cable may be fed into the junction box to provide electrical power to
another light fixture intended to be on the same circuit. No more than two
cables can be fed into the junction box. It is very important that the knockout
used for the second cable be adjacent to the knockout used for the first
cable. Avoid using a knockout that is on the opposite side of the first
knockout.
Using an opposite knockout may make insertion through the
ceiling hole more difficult.
LIGHT BULB AND TRIM INSTALLATION (Fig. 15, 16, 17 & 18)
1. Follow one of the figures below to install the trim and light bulb.
2. To install the trim, squeeze both torsion springs together and insert into
the can's receiver brackets and release. Carefully push the trim into can.
3. Installation is complete. Restore electrical power.
Fig. 15
Socket
Light
bulb
Trim
Fig. 17
TROUBLESHOOTING
SYMPTOM
POSSIBLE CAUSE
Wall sw itch or circuit breaker is
off.
Incorrect or loose w ire
connections
The light does not turn
on.
Light bulb may be dead. Test light
bulb in a know n w orking light
fixture.
Light bulb is loose.
The light is turning off
after being on for
some time. Soon after,
The thermal sensor turning off
it turns back on. The
due to excessive heat.
light continues this
cycle indefinitely.
COMMERCIAL ELECTRIC
2455 PACES FERRY RD. NW, ATLANTA, GA 30339
Torsion
springs
Receiver
bracket
Socket
Light
bulb
Trim
Light
bulb
SOLUTION
Turn on sw itch or circuit breaker.
Check w ire connections
Replace light bulb.
Tighten light bulb in socket.
Space aw ay any insulation at
least 3" (7,6 cm) from the
housing, as show n in Fig. 1.
Light
bulb
Fig. 16