Stopping The Generator; Normal Operation; During An Emergency - Westinghouse WGen9500DF Mode D'emploi

Masquer les pouces Voir aussi pour WGen9500DF:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OPERATION
MANUALLY STARTING THE GENERATOR
Be sure to check oil levels before starting. If it is the first
time starting make sure to add oil (see Adding Engine
Oil).
1. Make sure nothing is plugged into power outlets
2. Make sure the circuit breakers are properly set (see
Figure 8).
3. Select fuel source (see Step 4 on page 22)
4. Push the engine control switch into the RUN position
(see Figure 11).
5. Manually set the choke:
a. Cold Start: Close the choke by moving it right
towards the front handle of the generator.
Choke position for cold start.
b. Warm Start: Open the choke by moving it left
towards the wheels of the generator.
Choke position for warm start.
6. Firmly grasp and pull the recoil handle slowly until
you feel increased resistance. At this point, apply a
rapid pull while pulling up and slightly away from the
generator (see Figure 12).
Figure 12 - Pull recoil
7. Plug in electric devices.

STOPPING THE GENERATOR

Normal Operation

During normal operation, use the following steps to stop
your generator:
1. Remove any connected loads from the control panel
receptacles.
2. Allow the generator to run at "no load" to reduce and
stabilize engine and alternator temperatures.
3. Choose from options below to stop the generator
(see Figure 13):
• Position the engine control switch to STOP
• Hold push button start until the generator stops
• Hold the STOP button on the remote start key
fob (Note: The generator will run for an additional
8 seconds as it goes through a cool down cycle
before shutting off.)
Figure 13 - Stopping the generator
NOTE If you plan to store the generator after use,
stop the generator by turning the fuel shutoff
valve to the OFF position and allow the fuel to be
consumed from the carburetor.
4. If running off of propane then close the propane
valve. If running on gas turn the fuel shutoff valve to
the OFF position.

During an Emergency

If there is an emergency and the generator must be
stopped quickly, position the engine control switch to the
STOP position immediately.
Westinghouse Outdoor Power Equipment | 23
START
STOP

Publicité

Table des Matières
loading

Table des Matières