1. PRECAUTIONS AND SAFETY MEASURES
• To avoid false readings that can lead to electrical shock and/or injury, replace the batteries
as soon as the low battery indicator appears. Check Meter operation on a known source
before and after use.
• Use only AA batteries, properly installed in the Meter case, to power the Product
(see Section 5.1: Battery Replacement).
• When servicing, use only specified user serviceable replacement parts.
• Adhere to local and national safety codes. Individual protective equipment must be used to
prevent shock and arc blast injury where hazardous live conductors are exposed.
• Only use the test lead provided with the Product or UL Listed Probe Assembly rated CAT III
600 V or better.
• Do not use the HOT STICK (TIC 410A) to operate the AT-6000-R Receiver at voltages above 600 V.
• Remove the batteries if the Meter is not used for an extended period of time, or if stored
in temperatures above 50 °C (122 °F). If the batteries are not removed, battery leakage can
damage the Meter.
• Follow all battery care and charging instructions from the battery manufacturer.
• Do not use the Product to check for absence of voltage. Please use a voltage tester instead.
This manual contains information and warnings that must be followed for safe operation
and maintenance of the instrument. If the Product is used in a manner not specified by the
manufacturer, the protection provided by the Product may be impaired. This Product meets
water and dust protection IP52 (Receiver) and IP40 (Transmitter and signal clamp) per IEC
60529. Do NOT operate outside during periods of rainfall. The Product is double insulated for
protection per EN 61010-1 to CAT III 600 V.
CAUTION: Do not connect the Transmitter to a separate ground in Electrically Susceptible Patient
areas of a health care facility. Make the ground connection before disconnecting.
Your shipping box should include:
AT-6010-RE RECEIVER
AT-6010-TE TRANSMITTER
TEST LEAD AND ACCESSORY KIT*
CC-6010-EUR SOFT CARRYING CASE
USER MANUAL
1.5 V AA (IEC LR6) BATTERY
*TEST LEAD AND ACCESSORY KIT
• 1 x 1 m test lead (red)
• 1 x 7 m test lead (green)
• 2 x test probes (red, black)
• 1 x alligator clip (black)
Optional accessories:
ADPTR-SCT-xx Socket adapter
HS-1 Magnetic hanger
TL-7000-25M Test lead
CT-400-EUR Signal clamp
Replacement test lead and accessory kit: TL-7000-EUR
AT-6010-EUR KIT