Télécharger Imprimer la page
Honeywell FocusPRO TH5000 Serie Guide D'installation
Honeywell FocusPRO TH5000 Serie Guide D'installation

Honeywell FocusPRO TH5000 Serie Guide D'installation

Masquer les pouces Voir aussi pour FocusPRO TH5000 Serie:

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

FocusPRO
Non-Programmable Digital Thermostat
This manual covers the following models
• TH5110D: For 1 Heat/1 Cool systems
• TH5220D: For up to 2 Heat/2 Cool systems
(Remove battery holder to find model number)
System Types
• Gas, oil, or electric heat with air
conditioning
• Warm air, hot water, high-
efficiency furnaces, heat pumps,
steam, gravity
Must be installed by a trained, experienced technician
Read these instructions carefully. Failure to follow these instructions
can damage the product or cause a hazardous condition.
For assistance with this product please visit
or call Honeywell Customer Care toll-free at
® U.S. Registered Trademark. Patents pending.
Copyright © 2006 Honeywell International Inc.
All rights reserved.
TH5000 Series
TM
Need Help?
Installation
Guide
• Heat only — two-wire systems,
three-wire zone valves (Series
20), and normally open zone
valves
• Heat only with fan
• Cool only
• 750 mV heating systems
http://yourhome.honeywell.com
1-800-468-1502
69-1922EF

Publicité

loading

Sommaire des Matières pour Honeywell FocusPRO TH5000 Serie

  • Page 1 Need Help? For assistance with this product please visit http://yourhome.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502 ® U.S. Registered Trademark. Patents pending. Copyright © 2006 Honeywell International Inc. All rights reserved.
  • Page 2 Installation Guide Wallplate installation 1. Separate wallplate from thermostat. It's easier to grasp the wallplate and remove it after completely 2. Mount wallplate as shown below. removing the battery holder. Remove battery holder. Pull here to remove wallplate from new thermostat. Drill 3/16”...
  • Page 3 FocusPRO TH5110 / TH50 Power options Keep wires in this shaded area Remove factory- installed jumper only for two- transformer systems. Insert batteries for primary or backup power. Connect for primary AC power (optional if batteries are installed). Wiring Terminal designations Shaded areas below apply only to TH5220D.
  • Page 4 L terminal sends a continuous output when Remove jumper for 2-transformer systems. thermostat is set to Em. Heat. Connect Optional 24VAC common connection. to Honeywell zoning panels to switch the Common connection must come from panel to Emergency Heat. cooling transformer.
  • Page 5 FocusPRO TH5110 / TH50 Wiring Wiring guide — heat pump systems Shaded areas below apply only to TH5220D. 1H/1C Heat 2H/1C Heat Pump System Pump System Power Power [R+Rc joined by jumper] [R+Rc joined by jumper] Compressor contactor Compressor contactor 24VAC common 24VAC common Changeover valve...
  • Page 6 Installation Guide Installer setup Follow the procedure below to configure the thermostat to match the installed heating/cooling system, and customize feature operation as desired. Function Setting number Done Next Press to change settings. Press NEXT to advance to the next function. To begin, press and hold the and FAN Press DONE to exit and save settings.
  • Page 7 FocusPRO TH5110 / TH50 Installer setup Setup function Settings & options (factory default in bold) Shaded areas below apply only to TH5220D. Stage 1 compressor Recommended for most compressors cycle rate (CPH) [Other cycle rate options: 1, 2, 4, 5 or 6 CPH] Stage 2 compressor Recommended for most compressors cycle rate (CPH)
  • Page 8 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 4Z9 http://yourhome.honeywell.com Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers. ® U.S. Registered Trademark. © 2006 Honeywell International Inc. 69-1922EF M.S. 03-06...
  • Page 9 Pour obtenir de l’assistance au sujet de ce produit, consulter le http://yourhome.honeywell.com ou téléphoner sans frais au Centre de service à la clientèle de Honeywell au 1-800-468-1502 ® Marque de commerce déposée aux É.-U. Brevets en instance. © 2006 Honeywell International Inc.
  • Page 10 Guide d’installation Installation de la plaque murale 1. Séparer la plaque murale du thermostat. Il est plus facile de saisir la plaque murale et de l’enlever 2. Installer la plaque murale tel que décrit après avoir complètement ci-dessous. retiré le porte-pile. Retirer le porte-pile.
  • Page 11 FocusPRO TH5110 / TH50 Options d’alimentation Garder les fils dans Enlever le cavalier cettezone installé en usine ombragée. uniquement pour les systèmes à deux transformateurs. Insérer les piles pour l’alimentation primaire ou de secours. Brancher pour l’alimentation CA primaire (facultatif si des piles sont installées). Câblage Désignation des bornes Les zones ombragées ci-dessous s’appliquent seulement au TH5220D.
  • Page 12 La borne L envoie un signal continu lorsque à 2 transformateurs. le thermostat est réglé à Em. Chauffage Connexion facultative au neutre 24 V CA. Brancher aux panneaux de zones Honeywell La connexion du neutre doit venir pour commuter le panneau au chauffage du transformateur de climatisation.
  • Page 13 FocusPRO TH5110 / TH50 Câblage Guide de câblage – systèmes de thermopompes Les zones ombragées ci-dessous s’appliquent seulement au TH5220D. Système de Système de thermopompe 1C/1C thermopompe 2C/1C Alimentation Alimentation [R+Rc reliés par le cavalier] [R+Rc reliés par le cavalier] Contacteur de compresseur Contacteur de compresseur Neutre 24 V CA...
  • Page 14 Guide d’installation Configuration du système Suivez la procédure ci-dessous pour configurer le thermostat pour correspondre au système de chauffage et de climatisation installé, et pour paramétrer les fonctions tel que voulu. Réglage Numéro de fonction DONE NEXT Appuyer sur pour modifier les réglages.
  • Page 15 FocusPRO TH5110 / TH50 Configuration du système Fonction de Réglages et options configuration (réglages par défaut en gras) Les zones ombragées ci-dessous s’appliquent seulement au TH5220D. Rythme de cycle de Recommandé pour la plupart des compresseurs compresseur de stade [Autres options de rythme de cycle : 1, 2, 4, 5 ou 6 CPH] 1 (CPH) Rythme de cycle de Recommandé...
  • Page 16 Golden Valley, MN 55422 Scarborough (Ontario) M1V 4Z9 http://yourhome.honeywell.com Imprimé aux É.-U. sur du papier recyclé contenant au moins 10 % de fibres de papier recyclées après consommation. ® Marque de commerce déposée aux É.-U. © 2006 Honeywell International Inc. 69-1922EF M.S. 03-06...

Ce manuel est également adapté pour:

Focuspro th5110dFocuspro th5220dFocuspro th5320u