Cartridge Installation
The ViruStat® microbial purification cartridge is for use with the MyBottle personal portable water
purification system as a microbiological water purifier. Each replaceable ViruStat® microbial
purification cartridge will treat up to 26 gallons (100 liters) of water.
Changing the Cyst Filter
When water flow becomes restricted, use the following steps to change the Cyst Filter:
a. Remove the cartridge/bottle cap from the bottle.
b. Remove the Cyst Filter from the bottom of the ViruStat® cartridge.
c. Gently twist and push the new Cyst Filter onto the ViruStat® cartridge (see Figure 1).
d. Put cartridge/bottle cap back on bottle.
Changing the V V i i r r u u S S t t a a t t ® ® Microbial Purification Cartridge
After 26 gallons (100 liters) use the following steps to change the ViruStat® cartridge:
a. Remove the cartridge/bottle cap from the bottle.
b. Remove the ViruStat® microbial purification cartridge with the Cyst Filter and Postfilter from the
cap. Discard cartridge components in trash receptacle.
c. Flush Postfilter (see step 2 of product set-up).
d. Assemble the cartridge (see step 3 of product set-up).
e. Follow the Pre-Conditioning procedure.
Checking the Lifespan of the V V i i r r u u S S t t a a t t ® ® Microbial Purification Cartridge
The MyBottle comes with an cartridge life counter. This integrated mechanism inside the bottle cap
indicates when to replace your filter cartridge.
a. Before each filling remove the cartridge/bottle cap from the bottle.
b. Remove the ViruStat® microbial purification cartridge with the Cyst Filter and Postfilter from the
cap and lay aside.
c. Carefully rotate the life counter in a clockwise direction until it snaps into the next position. This
is best done holding the bottle cap in both hands.
d. When the life counter is back at the starting point it is time to replace the cartridge.
e. Only use the included straw instead of purification cartridge if water source has been treated
and is safe for drinking (like most tap water).
Opening
for straw
Cartridge life counter
"START" position
(8)
Cleaning
Wash and dry the inside of the MyBottle thoroughly before using and regularly during heavy
periods of use. If using with safe water and without the ViruStat® cartridge, the bottle must be
completely disinfected to prevent contamination from previous contact with contaminated water.
Your MyBottle and the cap are dishwasher safe (without the cartridge). The rubber mouth piece
cover may be removed for cleaning it thoroughly. Do NOT use soap to clean the ViruStat®
cartridge, the Cyst Filter or the Postfilter.
Before storage, remove excess water from the ViruStat® cartridge by disassembling all three
components. Shake out excess water. Allow the components to thoroughly dry. Wash and dry
bottle. Wash well and follow conditioning instructions before resuming use. Replace a used Cyst
Filter when taking the MyBottle system out of prolonged storage.
D D o o N N O O T T use with carbonated or flavored beverages, as they may damage the ViruStat®
microbial purification cartridge.
IMPORTANT
Refer to the Important Notes and the Product Set-Up before using.
Storage & Disposal
Storage
Store purification components in a cool, dry place or in a refrigerator (not in the freezer section).
Store empty bottle (without ViruStat® cartridge, Cyst Filter or Postfilter installed) with the cap on.
Disposal of used cartridges or filters
Do not reuse spent cartridges or filters; place in trash or offer for recycling if available.
(9)