5. UK – Product information
The exodraft chimney fan type RS is supplied with location brackets, armoured cable, safety wire
and mineral wool mat for vibration-free mounting.
(Two wing screws are also included, to be used where conditions allow).
Bad lighting habits can result in problems with soot, chimney ires, etc. which might damage the
chimney fan. Please see our advice about lighting and maintaining a ire at
www.exhausto-cdt.com or www.exhausto.co.uk
Warning! All installations must be carried out by competent personnel in
accordance with national laws and regulations
Avoid chimney ires – ensure that the chimney has been swept before
mounting the fan.
The chimney fan must always be operating when the ireplace is in use.
Please always read the installation instructions for the exodraft control
unit, before installation of the chimney fan.
If the exodraft fan system has been designed for solid fuel/multi fuel
installations then please ensure the design meets the requirements of
BS EN15287-1. If this can not be achieved, then a smoke alarm must be
installed in the same room as the appliance.
exodraft would always recommend the use of a smoke alarm when a solid
fuel open ire is installed.
Fans serving biomass boilers will inevitably receive a deposit from
the appliance. Especially on biomass Boilers IT IS ESSENTIAL THAT
A REGULAR INSPECTION AND CLEANING REGIME IS IMPLEMENTED,
ESPECIALLY IN THE EARLY DAYS OF USAGE, TO ESTABLISH A PATTERN FOR
TIMING OF REGULAR INSPECTIONS AND CLEANING.

5.1 Construction and design

The body and casing are manufactured in cast aluminium, the RS fan is designed for
horizontal discharge. It is available in six sizes: the RS 009, 012, 014, 016, 255 and 285.
All types can be opened for service and cleaning purposes.
Size and weight
Chimney fan
RS009-4-1
RS012-4-1
RS014-4-1
RS016-4-1
RS255-4-1
RS285-4-1
Weight
Vane/impeller
9 kg
Stainless steel vane
14 kg
18 kg
Stainless steel vane
25 kg
14 kg
Cast aluminium impeller
20 kg
UK •