Read the complete manual before attempting installation and activating the system.
1. DESCRIPTION
This flush-mounting push button dimmer with reverse phase control has a maximum load of 100 W and is
suitable for dimming Philips
©
LED fixtures (see 3.4.) and dimmable economy lamps. Remote control via NO
contacts. Maximum of 30 non-illuminated push buttons in parallel.
2. MOUNTING AND CONNECTIONS
To connect the load and the necessary power supply voltage, see the wiring diagrams below ➥➊. To regulate
the minimum level in cases of incorrect light output, see ➥➋. For installation, see ➥➌.
3. OPERATION AND USE
3.1. Normal operation
Remote control unit via NO contacts (not illuminated). Press briefly to switch on and off. Hold down to dim
up and down. When holding down, the dimming direction is switched after each interruption (dimming up
-> stop -> dimming down-> stop -> dimming up -> etc.). Once the maximum intensity has been reached,
the dimming level remains unchanged. The last dimming level reached before the dimmer is switched off is
saved in a memory (3.3.). Up to 30 NO contacts (170 00000) can be connected in parallel (max. distance
100 m). The push buttons are not galvanically isolated.
3.2. The dimmer works according to the reverse phase control principle.
3.3. Memory function
The dimmer can be used with or without memory. The standard setting of the dimmer is without memory
function. To change this setting, dim up to the maximum light level and then hold the control button in for
10 s. After 10 s., the light dims from 100% to a lower light level to indicate that this function has been
switched on. After this change in light intensity, immediately release the push button. Repeat the procedure to
deactivate the memory function. This function, and the last set light level, is stored in a non-volatile memory,
i.e. they will not be lost in the event of a power failure. With the memory function, the dimmer switches on for
the first time at a light level chosen by the manufacturer. Thereafter the dimmer switches on at the last set
value.
TIP! When using dimmable economy lamps, we recommend switching off the memory function.
With memory
- Press briefly = on at previous level/off
- Hold down when off = the dimmer dims up from the minimum light level
- When dimming up, the dimmer stops at the maximum
- When dimming down, the dimmer stops for 2 s. at the minimum and then dims back up
- A renewed (long) press reverses the dimming direction
Without memory
- Press briefly = on at maximum/off. Apart from that, the control is analogous to the control with memory.
- Push button control:
brief press < 400 ms;
holding down > 400 ms
= on/off
= dimming up/dimming down
3.4. Lamps
- Philips
©
LED fixtures
- Ledino
- Roomstylers
- Arcitone
- Smartspot
- Lirio by Philips
- Topselection of Massive
- Dimmable economy lamps CFLi
- Electronic transformers
- Halogen 230 V
See table below
4. TROUBLESHOOTING
- Possible causes of dimmer malfunction:
- the dimmer is switched off; the load is not dimmable in reverse phase control;
- the mains voltage is not connected;
- the load is not connected or is too high;
- the lamp or the cable used is defective;
- the connected load is not suitable (e.g. a ferromagnetic transformer);
- the thermal protection has been activated;
- a combination of the above causes.
Philips
©
LED fixture
type 30 W
Lamp
Max.
3 units
Min.
1 unit
nv Niko sa
Philips
©
LED fixture
type 7,5 W
HAL. 230 V
HAL. 230 V
10 units
100 W
100 W
1 unit
2 W
2 W
Industriepark West 40, BE-9100 Sint-Niklaas, Belgium — tel. +32 3 778 90 00 — fax +32 3 777 71 20 — e-mail: support@niko.be — www.niko.eu
- The dimmer is equipped with thermal protection. If the temperature climbs too high as a result of
overloading, the dimmer switches off. If this happens:
- check whether the load is too high;
- check whether mixed loads are being used;
- check whether the minimum dimming level is set too low (for operation with memory);
- check the ambient temperature and positioning conditions. Depending on these factors, the maximum
connection output must be reduced as follows:
- d
5. USAGE WARNINGS
- Control signals that are sent via the mains can interfere with the operation of the dimmer. (This is not a defect.)
- This dimmer produces a limited amount of heat under normal operating conditions. Allow for sufficient heat
dissipation; do not cover the dimmer with insulating material.
- Reaction of the device after a power failure: return to the previous setting with memory/without memory.
- The dimmer is never electrically separated from the mains due to the operation of the control. In other words,
all parts remain connected to the power even if the load (e.g. the light) is "off".
- This appliance is not suitable for controlling motors and ferromagnetic mains transformers.
6. TECHNICAL DATA
- Power supply voltage: 230 Vac ± 10%, frequency 50 Hz
- Mounting: this dimmer fits in a standard flush-mounting box with a min. depth of 40 mm
- Weight: ± 75 g
- Ambient temperature (Ta): 35°C
- Designed for use in an environment with non-condensing humidity
- No-load power consumption: ± 0.6 W (unloaded)
- Maximum wire diameter per connection terminal: 2.5 mm²
- Power supply and load: 2 x 1.5 mm
or 1 x 2.5 mm
2
- Push button input: 2 x 1.5 mm
2
or 1 x 2.5 mm
- Minimum load: 2 W
- Maximum load: 100 W
- No voltage drop over the dimmer
- Protections: thermal overload protection; short circuit protection
- Push button controls: 230 V, 5 mA (not galvanically isolated)
- Max. distance to the last push button: 100 m
- Complies with the EN60669-2-1 standards
7. WARNINGS REGARDING INSTALLATION
- The installation should be carried out by a registered installer and in compliance with the statutory
regulations.
- This user manual should be presented to the user. It should be included in the electrical installation file, and
it should be passed on to any new owners. Additional copies are available on the Niko website or via the Niko
support service.
- During installation, the following should be taken into account (non-exhaustive list):
- the statutory laws, standards and regulations.
- the technology currently available at the time of installation.
- this user manual, which only states general regulations and should therefore be read within the
scope of each specific installation.
- the rules of proper workmanship.
This product complies with all of the relevant European guidelines and regulations. If applicable, you can find
the EC declaration of conformity regarding this product at www.niko.eu.
8. NIKO SUPPORT
In case of doubt or for the specific exchange procedure in case of a possible defect, contact the Niko support
service in Belgium at +32 3 778 90 80 or your wholesaler/installer. Contact details and more information can
be found at www.niko.eu under the "Help and advice" section.
9. GUARANTEE PROVISIONS
- The period of guarantee is four years from the date of delivery. The delivery date is the invoice date of
purchase of the product by the consumer. If there is no invoice, the date of production applies.
- The consumer is obliged to inform Niko in writing about the non-conformity, within two months after stating
the defect.
- In case of a non-conformity, the consumer only has the right to a product repair or replacement free of
charge, which shall be decided by Niko.
- Niko shall not be held liable for a defect or damage resulting from incorrect installation, improper or
careless use, incorrect operation, transformation of the product, maintenance that does not adhere to the
maintenance instructions or an external cause, such as damage due to moisture or overvoltage.
- The compulsory regulations of the national legislation concerning the sale of consumer goods and the
protection of the consumer in the countries where Niko sells, directly or via sister companies, subsidiaries,
chain stores, distributors, agents or permanent sales representatives, take priority over the above-mentioned
rules and regulations.
Key to symbols
dimmable
100 W
100 W
2 W
2 W
2
2
Metal filament lamps
Electronic transformers
PM310-0280XR12432

Publicité

loading

Ce manuel est également adapté pour:

310-02800310-02801