Trouble Shooting - Deltafox DP-CCG 1830 Traduction De La Notice D'utilisation Originale

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 43
GB

Trouble shooting

In the event of an accident or malfunction, remove the battery from the device
immediately! Failure to comply may result in injuries from cuts.
Problem
Device does not
start.
Machine works
with interruptions
Sealant/glue does
not come from the
cartridge
Sealant/glue is es-
caping in the back
of the cartridge
28
Possible cause
Battery (12) not inserted
Rechargeable battery (12)
discharged
On/off switch (7) is defective.
The motor is defective.
Internal loose contact
On/off switch (7) is defective.
Cartridge is empty
Sealant/glue in the cartridge
dried up
Sealant/glue in the cartridge
frozen
Cartridge not opened
Cartridge opening/cartridge
nozzle plugged
Feed rate too high
Error correction
Insert the battery (12) (see "In-
serting/removing the battery")
Charge the battery (12) (ob-
serve the separate operating
instructions for the rechargeable
battery and charger)
Repairs must be carried out by
our Customer Service depart-
ment.
Repairs must be carried out by
our Customer Service depart-
ment.
Insert a new cartridge
Insert a new cartridge
Insert a new cartridge
Open the cartridge
Force through the plugged car-
tridge opening/cartridge nozzle
using the integrated pin (11)
Lower the feed rate using the
controller (8)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dp-ccg 1830 set

Table des Matières