Schenck Process DISOMAT Opus Instructions De Service page 55

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
®
DISOMAT
Opus – Operating Instructions
© Schenck Process GmbH, Darmstadt
'Test/Zero Set - Acknowledge Error'
Test display and set scale to zero = touch key less than 1
sec.
Display test is performed. Scale is set to zero. Zeroing is
possible only if scale is in no-motion and weight of load on
scale in zeroing range.
During display test, a check number measurement is
performed. During this time, no 'normal' weights are acquired.
Therefore, all comparators go to 'safe state', i.e. all
overload/underload contacts drop/respond.
Acknowledge event message = press key longer than 1 sec.
Event class 'S' messages (=Fault) can be acknowledged on
DISOMAT keyboard after password input.
'Weigh and Print'
Corresponds to F4 key on device.
Use key for single printout (weigh slip) after every weighing
operation. DISOMAT uses print pattern 2.
New printout is possible only after relief of crane.
'Print Total / Clear Balance'
Corresponds to F6 key on device.
Use key to perform totals printout after one or multiple weighing
operations. The cumulative weight value of all weighing
operations is printed. Then, value (cumulative weight) is
cleared, i.e. totals weight and number of weighing operations
are set to zero. DISOMAT uses print pattern 3.
Scale Specific Control
0630
BV-H2322 AA