Elcometer SAGOLA mack 150 Manuel D'utilisation page 28

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 91
Directives and regulations
Directive Machine
ATEX regulation
(*) Non electric equipment in explosion hazard areas (ATEX) must have the earthing connections and/or sta-
tic-free feed hoses.
Fluid pressure scheme
MACK 150
Pressure ratio 15:1
Air inlet pressure
3 bar
43.5 psi / 0.3 MPa
5 bar
72.5 psi / 0.5 MPa
7 bar
101.5 psi / 0.7 MPa
Equipment identification
The equipment is provided with the manufacturer's identification plate, shown in the picture
below. For no reason must the plate be removed, even if the equipment must be re-sold. For
any communication with the Sagola always refer to the serial number written on the plate itself.
an Elcometer company
Urartea 6, 01010 Vitoria. Made in Spain
2006/42/UE
Community directive complied with 2014/34/UE
Explosive atmosphere (Atex):
Product outlet pressure
39 bar
566 psi / 3.9 MPa
65 bar
943 psi / 6.5 MPa
91 bar
1,320 psi / 9.1 MPa
Fig.01
ENGLISH
II 2G T4 x (*)
MACK 320/320 MIX
Pressure ratio 32:1
Air inlet pressure
3 bar
43.5 psi / 0.3 MPa
5 bar
72.5 psi / 0.5 MPa
2,350 psi / 16.2 MPa
7 bar
101.5 psi / 0.7 MPa
3,278 psi / 22.6 MPa
Mod.
Nº Serie
Product outlet pressure
97 bar
1,406 psi / 9.6 MPa
162 bar
226 bar