VEK MNE2–R24-H
VEK MNE2–R230-H
LED Channel 1
DIP-Switch 1...8
LED Channel 2
DIP-Switch 9...12
Diagnostic (USB)
Reset-Button
1
Characteristic features
11-pole circular connector
Galvanic separation of loop and detector electronics
Automatic system adjustment directly after power-on
Sensitivity adjustment independent of loop inductivity
Loop busy signal emitted by LED-display
Potential-free relay contacts at the outputs
Loop fault message via LED-signal
Indication of historical loop fault
Continuous rebalancing of frequency drifts in order to avoid environmental
influences
Diagnostics by external Service Program via USB-Mini connector
2
Settings
Use the following DIP Switches for the standard settings.
2.1 Sensitivity
DIP 1
DIP 2
Function
DIP 3
DIP4
OFF
OFF
Low
ON
OFF
Medium Low
OFF
ON
Medium High
ON
ON
High
2.2 Frequency
DIP 5
Function
OFF
Low
ON
High
2.3 Hold Time
DIP 6
Function
OFF
5 Minutes
ON
Infinite
2.4 Output Mode Relay 2
DIP 7
Function
OFF
Presence Output on Relay 2
ON
Pulse Output on Relay 2
2.5 Output Edge Relay 2
DIP 8
Function
OFF
Pulse on Loop Entry
ON
Pulse on Loop Exit
2.6 Direction Mode
DIP 9
Function
OFF
Presence Output
ON
Direction sensitive Output
2.7 Direction Logic
DIP 10
Function
OFF
Dir. Logic Presence Output
ON
Dir. Logic Pulse Output
2.8 Fail Save / Fail Secure
DIP 11
Function
DIP 12
OFF
Inverted Output Signal
ON
Non Inverted Output Signal
More settings (Delay, Extension, Loop Fail Output, ..) or more detailed settings
(Sensitivity, Hold Time, Output Modes, ..) can be done via USB Interface with the
Service Program.
VEK MNE2-R24-H /-R230-H
Double-Channel Inductive Loop Detector
DIP 1/2
Loop 1
DIP 3/4
Loop 2
More detailed Sensitivity
settings via USB Interface!
More detailed Hold Time
settings via USB Interface!
Setting doesn't affect
Relay 1!
Available only if
Relay 2 is in Pulse Output
Mode!
Available only if Direction
Sensitive Output is active!
DIP Switch 11 inverts
output signal on
Relay 1 and DIP Switch 12
on Relay 2.
30.05.2016
Operating Instructions
3
Reset-Button
Pressing
LED-
Operation
push button
display*
Triggers a hardware reset with recalibration
red LED
1 s
and resets the LED output for resolved loop
flashes
faults
blue LED
Triggers factory settings and resets USB-
5 s
flashes
overwrite
*) Only LEDs on channel 1 are used to display the activation via the push button!
4
LED
Red
Blue
Function
OFF
OFF
No supply voltage
Fast
OFF
Calibration/Retuning Loops
Flashing
OFF
ON
Ready for operation, Loop free
ON
ON
Ready for operation, Loop active
ON
OFF
Loop Fault
Historical Loop Fault or DIP Switch setting
x
Flashing
overwritten by USB*
Blinking
Blinking
Output Loop Frequency in kHz
*) If one or more DIP Switch setting is overwritten by the service program via USB
interface.
Example for loop frequency 57 kHz:
Tens
5x10 kHz
5
Diagnostics
To display more details of the induction loop system, e.g. frequency, detuning, busy
time, output signals, .. use the Service Program.
6
Pin Assignment
Pin
Function
1
Power
+10-30 VDC
2
Power
GND
3
Relay 2 N.O.
4
Relay 2 COM
5
Relay 1 N.O.
6
Relay 1 COM
7
Loop 1
8
Loop 1
9
-
10
Loop 2
11
Loop 2
7
Technical Data
Dimensions (H x W x L)
76 x 38 x 71 mm
-R24: 10-30 V AC/DC, max.1 W
Power Supply
-R230:100-240 V AC, 50-60 Hz, max. 2 W
Operating Temp.
-37 °C...+70 °C
Relays
max. 2 A, 230 VAC, 60 W/125 VA
Loop
Inductivity
20-700 µH, recommended 100-300 µH
Frequency
30-130 kHz, 2 steps
Supply Line
max. 200 m
Resistance
max. 20 Ohm, incl. Loop Supply Line
Connectors
Power, Loop,
11-pole circular connector
Relay.
Diagnostic
USB-Mini AB
Additional note: Maybe only one frequency adjustment level is available when using
induction loops outside of the recommended range. Additionally using lower
induction loop values than recommended, can lead to reduced loop resistance
values.
Units
1 s
7x1 kHz
57 kHz
-R24
-R230
L 100-240 VAC
10-30 VAC
N