3 Product description
Heat exchanger
Submergible pump
• Delivery rate (Qmax.)
• Delivery rate at G3/8" water connection
• Delivery height (Hmax.)
Cooling capacity according to IEC 60974-2 with
Q-=1 l/min
• with BTC 15
• with deionized water
Sound level
Tank capacity
Protection type
Weight
Tab. 5
Device version GK XXXXX V
Motor
Nominal voltage (V)
Frequency (Hz)
Motor rating (kW)
Current consumption (A)
Tab. 6
Motor types relative to device version GK XXXXX S
EN - 8
The submergible pumps comply with the IP54 protection type according to
EN 60 529.
Each cooling unit can be delivered with one of the 3 motor types.
Type I
115
60
0,44
4,2
Coolant recirculator
WK23
2-row
18 l/min
approx. 9 l/min
36 m
1000 W
1100 W
approx. 69 db(A)
7 l
IP 23
17 kg
Type II
230
60
0,44
2,1
WK43
4-row
1250 W
1350 W
18 kg
Type III
220
50
0,32
1,7