NB!
It is forbidden to use a non-heat-resistant cable with PVC isolation
as the power cable. The joint box must be waterproof and it must be
located up to 50 cm from the floor.
L1
L2
L3 N
400V 3~
1.
Open the cover of the heater's electrical box.
2. Attach the power cable on the terminal block according to the
circuit diagram.
3. Close the cover.
4. Fix the cable on the output with a cable strap.
Fittingthestones
When laying stones, care must be taken to ensure that the heaters
do not bend and that sufficient air circulation is ensured. See the
figure below.
•
The heater can hold approximately 30 kg of stones.
•
We recommend washing the stones before laying them.
•
Stack the stones sparsely between the heating elements. If the
stones have been stacked too close to each other, the heating
elements may overheat (= shorter useful life) and slow the
heating of the sauna.
•
Stones with a diameter of 5-10 cm are suitable for the heater.
•
The heating elements must not be visible
•
The stones on the external surface of the heater must be
stacked close to one another.
•
The use of ceramic stones in the heater is allowed at your own
risk.
ATTENTION!
A too sparsely filled stone container causes fire hazard!
6