FUNCTIONS OF THE TERMINALS
Power 12Vdc
-
Test Power
Auto protection
USE OF THE RESET BUTTONS
3200290
Reset switch 1
Reset switch 2
Automatism
Open
Drain C No
Use this switch to restore the factory network settings (IP address:
192.168.2.150, mask 255.255.255.0).
Turn off the power.
Hold the switch down while turning the power back on
Wait until the relays engage (about 20 seconds) holding the switch down
Release the switch
Use this switch to clear the unit memory
Turn off the power.
Hold the switch down while turning the power back on
Wait until the relays engage (about 20 seconds) holding the switch down
Release the switch
Ethernet network
RS485
extension bus
License
Page 20/30
Nc
Normally closed
C
Common
No
Normally open
+12 Vdc/1,5Amax.
+
S/CLOCK/DATA1/A
S-BUS/CK / D1/A
DATAT/DATA0/B
DT/DT0/B
LED
LED
GND
-
Push button
Exit buttom
Door contact
Door sensor
Conditional
Conditional entry