Checking the air outlet filter
-
Loosen the screws (26 Fig. 18) and re-
move the cover 2737 Fig. 18).
-
Remove the foam tank (28 Fig. 19) and
the texture sponges (29 Fig. 20) if any.
-
Clean the sponges with a blast of air (Fig.
21).
The filter sponges can be washed in
warm water and must only be replaced
once they are completely dry; if too dirty,
replace them with new ones.
-
Reassemble all the parts by following the
dismantling process steps in the reverse
order.
PROBLEM
The vacuum cleaner does
not work.
Suction is not satisfactory.
Checking, cleaning the motor
protection filter and the floating
functionality
-
Remove the cylinder head as previously
indicated.
-
Remove the filter (4 Fig. 24).
-
Check If the floater (30 Fig. 23) is in
good condition and if it moves freely in its
space.
-
Wash the filter (4 Fig. 24) with warm run-
ning water removing all foreign particles
and reassemble only after a thorough
drying.
-
Insert the filter (4 Fig. 24) on the motor
hood then through the straps (31 Fig. 24)
hooking the elastic part on the top of the
filter with washers (32 Fig. 24).
-
Reassemble in reverse order.
CAUSE
Switch not pressed.
Plug not inserted.
No current.
Paper bag full.
Filter elements clogged.
Accessories
or
clogged.
Suction nozzle squeegee
worn or damaged.
ENGLISH - 4
SOLUTION
Press the switch.
Insert the plug into the sock-
et.
Check the power supply
line.
Replace the dust bag.
Clean the filter elements.
tubes
Check and clean the flexible
hose and the suction noz-
zle.
Check
and
squeegee.
replace
the

Publicité