Specification

17.8 Data table

Electrical data
Rated voltage
Rated output
Rated current
Fuse protection
Frequency
Phases
Resistivity ρ15 ≥
Conductivity σ15 ≤
Max. mains impedance at 50 Hz
Connections
Water connection
Application limits
Minimum supply pressure
Max. permissible pressure
Max. inlet temperature for reheating
Temperature setting range
Values
Max. inlet temperature (e.g. pasteurisation)
On
Flow rate at 28 K
Flow rate at 50 K
Pressure drop for flow rate at 50 K (without flow limiter)
Hydraulic data
Nominal capacity
Versions
Type of installation
Adjustable connected load
Protection class
Insulating block
Heating system heat generator
Cover and back panel
Colour
IP rating
Dimensions
Height
Width
Depth
Weights
Weight
Note
The appliance conforms to IEC 61000-3-12.
20
| DCE-X Premium
DCE-X 6/8 Premium
V
220
230
kW
6.0/8.0
6.6/8.7
A
27.3/36.4
28.5/38.0
A
Hz
Ω cm
μS/cm
Ω
0.0385
0.0368
MPa
0.18 (1.8 bar / 26 psi)
MPa
1 (10 bar / 150 psi)
°C
°C
°C
l/min
l/min
3.1/4.1 @ 220 V
l/min
1.7/2.3 @ 220 V
MPa
l
Oversink / undersink
mm
mm
mm
kg
Guarantee
The guarantee conditions of our German companies do not
apply to appliances acquired outside of Germany. In countries
where our subsidiaries sell our products a guarantee can only
be issued by those subsidiaries. Such guarantee is only grant-
ed if the subsidiary has issued its own terms of guarantee. No
other guarantee will be granted.
We shall not provide any guarantee for appliances acquired in
countries where we have no subsidiary to sell our products.
This will not affect warranties issued by any importers.
Environment and recycling
We would ask you to help protect the environment. After use,
dispose of the various materials in accordance with national
regulations.
DCE-X 10/12 Premium
238158
240
220
230
7.2/9.6
10.0/12.0
11.0/13.1
30.0/40.0
45.5/54.5
47.8/57.0
30/40
50/60
1/N/PE
1100
910
0.0353
0.0257
0.0245
G 1/2 A
0.18 (1.8 bar / 26 psi)
1 (10 bar / 150 psi)
55
Off, 20-60
70
1.3
0.01/0.01
0.277
Oversink / undersink
X
1
Plastic
Bare wire
Plastic
White
IP 25
372
217
109
2.5
www.stiebel-eltron.com
238159
240
12.0/14.3
50.0/59.5
50/60
50/60
1/N/PE
1100
910
0.0235
G 1/2 A
55
Off, 20-60
70
1.3
5.1/6.2 @ 220 V
2.9/3.5 @ 220 V
0.02/0.03
0.277
X
1
Plastic
Bare wire
Plastic
White
IP 25
372
217
109
2.5