appliance description

8.
Appliance description
8.1

Standard delivery

The following are delivered with the appliance:
- 2 x 45° twin nipples
- 2 flat gaskets
- 2 O-rings
- Cable grommet
- Strainer
- Jumper for anti-scalding protection, attached
- Jumper for output changeover, attached
8.2

Accessories

Installation kit for water installation on unfinished walls
(200016 - UP-Kit EU)
The installation kit for water installation on unfinished walls con-
tains:
- 2 x grommets to seal the apertures in the appliance back
panel.
- Strainer with sealed edge for installation on the 45° twin
nipple.
- Flat gasket
9.

Preparation

9.1

Installation site

Material losses
!
Install the appliance in a room that is free from the risk
of frost.
f Always install the appliance vertically and near the draw-off
point.
The appliance is suitable for undersink and oversink installation.
Undersink installation
1 Cold water inlet
2 DHW outlet
10
| DCE-X Premium
1
2
Oversink installation
2
1 Cold water inlet
2 DHW outlet
Note
f Install the appliance flush to the wall. The wall must
have sufficient load bearing capacity.
9.2

Minimum clearances

≥50
f Maintain the minimum clearances to ensure trouble-free op-
eration of the appliance and facilitate maintenance work.
9.3

Water installation

Material losses
!
Carry out all water connection and installation work in
accordance with regulations.
f Flush the water line thoroughly.
Fittings
Use appropriate pressure taps. Open vented taps are not per-
missible.
Permissible water line materials
- Cold water inlet line:
Pipes made from galvanised steel, stainless steel, copper or
plastic
- DHW outlet line:
Pipes made from stainless steel, copper or plastic
Material losses
!
If plastic pipework systems are used, take into account
the maximum inlet temperature and the maximum per-
missible pressure.
1
≥50
www.stiebel-eltron.com

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dce-x 10/12 premium

Table des Matières