5

Programming

In order to program the Ladebrückensteuerung, open the housing
cover.
The programming works in a menu-controlled fashion. Carry out
all settings as specified in the Programming procedure chapter,
see also Representation of the menu structure. The Program
overview chapter shows the full scope of the menu.
Programming procedure
Proceed as follows to carry out programming settings:
1.
Press the 
 button to reach the programming of the con-
trol. The selection of the individual main menu (in the fol-
lowing referred to as "menu") appears on the LED display.
Up to 9 menus are provided.
2.
Navigate with buttons 
The LED display shows the current selection as value 1-9.
3.
Confirm the selection with the button 
in the first digit now shows the menu which you are in. The
second digit shows the current menu item in this menu.
4.
Navigate with buttons 
item. A total of up to 10  menu items is provided to you
(0-9). The LED display shows the current selection in the
second digit as value 0-9.
5.
Confirm the selection with the button 
value for the respective menu item blinks on the LED dis-
play.
6.
Set the desired value using the buttons 
on the menu item, values between 0 and 99 can be
entered.
7.
Confirm the entry with the button 
confirms the entry by 5-time blinking of the LED point and
by returning to the selection of the menu item.
8.
If you want to complete the programming, press the but-
ton 
repeatedly until – – appears on the display.
9.
Confirm the selection with the button 
gramming.
16 - EN
 
to select the desired menu.
. The LED display
 
to select the desired menu
. The currently set
 
. Depending
. The LED display
to exit the pro-
Representation of the menu structure
Menu
1.
Activation of programming
2.
Menu selection
3.
4.
5. Confirmation of the
menu item selection
6. Setting of the desired value
7. Confirmation of the
setting
8. Navigation to the next
menu item or to exit
the programming
menu
9. Exit programming
Menu 1 Basic settings loading bridges
Overcurrent hydraulic motor (menu item 10)
Depending on the set current value, the control switches off the
pump if this value is exceeded.
In order to set the correct current value for the overcurrent, you
have to determine the actual value first. For adjusting, proceed as
follows:
TAR1 400V / 230V
Menu item
Selection
Confirmation of the
main menu selection
Selection of the menu
item
Exit