INSTALLATION
Installation
Installing the HP-SB 3/150 flanged immersion heater
1
1
Sheet metal casing earth
2
Flange gasket
3
Flange earth screw
4
Temperature selector
5
Control indicator
Electrical connection
WARNING Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
WARNING Electrocution
The connection to the power supply must be in the form
of a permanent connection. Ensure the appliance can be
separated from the power supply by an isolator
that disconnects all poles with at least 3 mm contact
separation.
Material losses
Observe the type plate. The specified voltage must match
the mains voltage.
Note
Ensure that the appliance is earthed.
f Feed the connecting cable into the control panel interior.
f
f Connect the load (see chapter "Specification / Wiring dia-
f
grams and connections").
www.stiebel-eltron.com
2
3
4
13
12
11
10
6
Flange cover
7
Screw 4.2x16
8
Washer 4.3
9
M12x25 screw
10
Washer 13
HP-SB 3/150
A Thermal fuse
B Temperature selector
C Control indicator
D Heating element
E Sheet steel casing
G Cylinder
H Rod anode
R Electrical resistance 560 Ω
5
9
11
Earth cable
12
Flange D = 180x5
13
Heating element
A
N
N
G
E
Flange earth screw
6
8
7
R
H
SB-VTI |