6.13 Setting "Follow-up time"
parameter
This parameter allows you to set after which
time the luminaire will be automatically
switched off when the sensors detect no
presence in their detection range.
You can set the follow-up times in six steps
of between 5 minutes and 30 minutes.
Factory setting: As-delivered, the follow-
up time is 10 minutes.
X Press both keys simultaneously and
keep them depressed for ten seconds.
The first LED on the light bar is lit.
X Press both keys again simultaneously
and keep them depressed for five sec-
onds.
The first and second LEDs on the light
bar are lit.
X Press both keys again simultaneously
and keep them depressed for five sec-
onds.
The first, second and third LEDs on the
light bar are lit.
X Release both keys.
One or more LEDs are lit. The remain-
ing LEDs are flashing.
30
Parameter setting | Explained step by step
X Set the desired follow-up time.
-
If you want to increase the follow-up
time, press the upper key.
-
If you want to decrease the follow-
up time, press the lower key.
The LEDs on the light bar that are lit
show the set follow-up time.
Fig. 8: Follow-up time = 5 minutes
Fig. 9: Follow-up time = 10 minutes
Fig. 10: Follow-up time = 15 minutes
Fig. 11: Follow-up time = 20 minutes
Fig. 12: Follow-up time = 25 minutes
Fig. 13: Follow-up time = 30 minutes
X Wait for ten seconds.
The setting is saved.