AXIS P1365 Network Camera
Power Consumption
NO TICE
NO
NO
TICE
TICE
Use a limited power source (LPS) with either a rated output power limited to ≤100W
or a rated output current limited to ≤5A.
Product
AXIS P1365
Connectors
I/O Connector
4–pin terminal block for:
• Auxiliary power (DC output)
• Digital Input
• Digital Output
• 0 V DC (-)
Function
Pin
1
0 V DC (-)
2
DC output
3–
Configurable
4
(Input or
Output)
PoE
DC
7.9W
8–28VDC, max. 7.7W
Notes
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
Digital input – Connect to pin 1 to activate,
or leave floating (unconnected) to deactivate.
Digital output – Connected to pin 1 when
activated, floating (unconnected) when
deactivated. If used with an inductive load,
e.g. a relay, a diode must be connected in
parallel with the load, for protection against
voltage transients.
1
2
3
4
14
Specifications
0 V DC
12 V D C
Max load = 50 mA
0 to max 30 V DC
0 to max 30 V DC, open
drain, 100 mA