Installation

5
Installation
5.1

Installation site (Qualified specialist)

5.1.1

Outdoor installation

In order to increase the pump's service life, provide simple
weather protection.
5.1.2

Installation position

The unit is normally installed on the narrow side of the pool
with a recommended minimum pool length of 4 m.
From a pool width of 4 m, installation on the longer side is
also possible.
For round and oval pools made from smooth sheet steel or
plastic, a minimum radius of 2 m is required.
For round and oval pools made from made from stone or
concrete, a flat surface with a minimum width of 480 mm is
required.
The water depth at the position of installation should be
between 1.2 m and 1.5 m. Thus the massage hose can be
used appropriately and optimally.
5.1.3

There must be ground drainage

Calculate the size of the ground drain according to the
following criteria:
Size of the swimming pool.
Circulation flow rate.
5.1.4

Ventilation and aeration

Ensure sufficient ventilation and aeration. The ventilation and
aeration must ensure the following conditions:
Prevention of condensation.
Minimum distance from fan cover to the wall: 120 mm.
Cooling of the pump motor and other system components,
for example switch cabinets and control units.
Limitation of the ambient temperature to maximum 40 °C.
5.1.5

Structure-borne and airborne noise transmission

Observe regulations for structural noise protection, for
example DIN 4109.
Install the pump in a manner which reduces structure-borne
and airborne noise transmission. Vibration-absorbing
materials are suitable bases. Examples:
Anti-vibration buffers
Cork lining
Sufficiently hard foam
18 EN
08|2020