NVision Multi Chemistry 50W Mode D'emploi page 18

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

 Precharge Time
When charging over-discharged batteries, the charger makes a slow charge before starting the fast
charge. This setting adjusts the duration of the slow charge. Slow charging over-discharged batteries
is recommended to avoid further damage to the batteries.
Precharge Time
OFF
 NiMH/NiCd delta-peak sensitivity
This setting adjusts the automatic delta-peak charge cut-off sensitivity. Use a higher value if the charge
tends to stop prematurely and a lower value if your battery is too hot at the end of the charge. Default
value is 7mV/cell for NiMh and 12mV/cell for NiCd.
NiMH Sensitivity
D.Peak Default
NiCd Sensitivity
D.Peak Default
 Temperature monitoring
The connector on the left panel can be used to connect an optional temperature probe for battery
temperature monitoring. You can adjust the battery charge cut-off temperature.
Temp Cut-Off
ON
80C(176F)
 Cycle delay
To prevent battery overheating during cycling, the charger can make a pause between the charge/
discharge cycles.
Wait Time
CHG >DCHG
5min
18
1min
nVision Multi Chemistry High-End Charger

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Multi chemistry 80wMulti chemistry 4x50w

Table des Matières