Hinged lid
As special design in the KFG3 -5, KFG5,
KFGS3-5, KFGS5 -5 series, lubricant can be filled
up through a hinged lid.
KFG3 -5
KFG5-5
KFGS3 -5
KFGS5 -5
Fig. 10 Hinged lid
Fill in only clean lubricant with the help
of a suitable tool.
Soiled lubricant leads to serious system
trouble !

2.6 Checking of filling level

Visual checking
The transparent lubricant vessel allows visual
checking of the filling level. Such checking needs
regularly to be carried out for safety reasons.
If the vessel was emptied below the
„min" mark, the entire system has to
be vented.
Automatic checking
The pumps of the KFGS series are provided for
automatic checking of the filling level. If the level
falls below the „min" mark, the lubrication process
is stopped with the error message „FLL" shown
on the display.
Page 14
Contents
Chapter
Operating Instructions KFG, KFGS

2.7 Venting of the system

Take off the main lines at the pump set. Keep
pumping until bubble-free lubricant emerges at the
screw fitting. Fit the main lines.
Take off the main line at the main distributor. Keep
pumping until there is no air in the line. Fit the main
line.
Take off the branch lines at the main distributor.
Keep pumping until bubble-free lubricant emerges
from all connectors of the main distributor. Fit the
branch lines.
Then vent the branch lines, branch distributors,
lubricant lines and lubrication points and check for
proper functioning.