PRODUCT CERTIFICATION

Depending on the particular model ordered, the heater is
suitable for the following areas:
CSA C/US Certified for Class I, Div 1, Groups A, B, C, D or
Groups C, D, CSA Type 4; Temp. Code T2 (215°C) T2D, T3, T3B,
T3C or T4
B.

PRE-INSTALLATION

1.
Initially, inspect the heater for possible damage due to
shipping and handling. Claims for shipping damages
shall be placed with the carrier.
2.
Check the heater nameplate to ensure that the heater
area classification and temperature code are suitable
for the hazardous area classification. For details of
hazardous locations with potential for explosion, refer to
the Canadian Electrical Code or National Electrical Code.
3.
Check to ensure that the heater voltage is the same as
the supply voltage.
4.
The heater must be installed by qualified personnel in
strict compliance with national and local electrical codes.
WARNING. Do not connect the heater to an electrical
supply voltage other than that shown on the
product nameplate.
WARNING
Figure 1 – Model XPAL/XPAS convection heater
C.

INSTALLATION

C.1
 General Requirements
1.
The XPA heater is intended for industrial use and is to
be mounted in an enclosure. The main function of this
heater is to prevent the damaging effects of moisture
and condensation on the components inside the
enclosure. It is not intended for comfort heating use.
2.
XPAL and XPAS heaters are approved for enclosure
mounting either horizontally or side mounted with the
junction box at the side. XPAR heaters are approved
for vertical mounting only with the junction box at the
bottom. Ensure that the enclosure is sufficiently strong
to support the heater which, depending on the model,
could weigh up to 15 lbs (7 kg).
ATEX
II 2G Ex db IIC or IIB, T2 (215°C), T3 or T4, Gb IP66
IECEx Ex db IIC or IIB, T2 (215°C), T3 or T4, Gb, IP66
NOTE:
- Standard XPA Models: -50°C to +40°C
- High Ambient XPA Models: -50°C to +55°C or 60°C
depending on model.
Figure 2 – Model XPAL/XPAS convection heater
Figure 3 – Model XPAR convection heater
3.
Do not recess the XPA heater into the wall. Use the
bracket supplied with the unit to ensure that the
minimum spacing from the wall of 1" (25 mm) is
maintained.
4.
If more than one heater is being installed, maintain at
least 3" (76 mm) between adjacent heater extrusions.
5.
The XPA heater relies on natural convection and "black
heat" radiation to transfer heat to the surroundings. See
Table 1, page 4 for minimum clearances above heater.
3 3