the other) and will require the use of a polarized extension cord. The plug will fit into a polarized
extension cord only one way. If the plug does not fit fully into the extension cord, reverse the plug.
If the plug still does not fit, obtain a correct polarized extension cord. A polarized extension cord
will require the use of a polarized wall outlet. The plug will fit into the polarized wall outlet only
one way. If the plug does not fit fully into the wall outlet, reverse the plug. If the plug still does
not fit, contact a qualified electrician to install the proper wall outlet. Do not change the
equipment plug, extension cord receptacle, or extension cord plug in any way.
b) LAWN MOWER-SPECIFIC SAFETY INSTRUCTIONS
Avoid dangerous environments – Don't use lawn mowers in damp or wet locations.
1)
2) Don't use in rain.
3) Keep children away – All visitors should be kept a safe distance from work area.
4) Dress properly – Do not wear loose clothing or jewellery. They can get caught in moving
parts. Use of rubber gloves and footwear is recommended when working outdoors.
5) Use safety glasses – In addition, always use a face or dust mask if operation is dusty.
6) Use right appliance – Do not use lawn mower for any job except that for which it is intended.
7) Ground fault circuit interrupter (GFCI) protection should be provided on the circuit(s)
or outlet(s) to be used for the lawn mower. Receptacles are available having built-in GFCI
protection and may be used for this measure of safety.
WARNING
To prevent electric shock use only with an extension cord suitable for outdoor use and
marked as such: SW, SOW, STW, STOW, SJW, SJOW, SJTW, or SJTOW.
8) Extension cord – Make sure your extension cord set is in good condition. When using an
extension cord, be sure to use one heavy enough to carry the current your product will draw.
An undersized cord will cause a drop in line voltage resulting in loss of power and
overheating. (NOTE: Table 1 shows the correct size to use depending on cord length and
nameplate ampere rating. If in doubt, use the next heavier gauge. The smaller the gauge
number the heavier the cord.)
Table 1 Minimum gauge for extension cords
Volts
120 V
Ampere Rating Min / Max
0 – 6
6 – 10
10 – 12
12 – 16
Total length of cord
25' ( 7.5 m)
50' ( 15 m)
18
18
16
14
16
16
16
12
I
contact us 1-844-428-7277
100' ( 30 m)
AWG
16
14
14
Not recommended
150' ( 45 m)
12
12