Preset 1 on-off
on = on
oFF = off
Permanent signal of output 1,
activated at count value
preset 1*
Permanent signal of output 1,
will become passive at count
value
preset 1**
Timed signal of output 1, will
become passive at count value =
preset 1**
Timed signal of output 1,
activated at count value = preset
1*
Duration of timed signal of output
1 can be set from 00.01 s to
99.99 s.
* Activation of relay coil or
optocoupler when reaching the
preset value
** Relay coil becomes dead or
optocoupler will be locked
when reaching the preset value
Permanent signal of output 2,
activated at count value
preset 2*
Permanent signal of output 2,
will become passive at count
value
preset 2**
Timed signal of output 2, will
become passive at count value =
preset 2**
Timed signal of output 2, activated
at count value = preset 2*
Duration of timed signal of output
2 can be set from 00.01 s to
99.99 s.
* Activation of relay coil or
optocoupler when reaching the
preset value
** Relay coil becomes dead or
optocoupler will be locked
when reaching the preset value
7. Programming of the Preset Value
After pressing one of the arrow keys, the leading zero
blanking will be suppressed for approx. 4 seconds and
the least significant digit of the preset value flashes with
a frequency of 1 Hz.
The value of the flashing digit can be increased by using
the
key. With the
key it will be changed to the next
digit. If no key is pressed for 4 seconds, the leading zero
blanking will be activated automatically again.
In operating mode Impulse Counter and Frequency
Meter the new value will be selected.
Caution! Do not change presets with output powered.
Setting Preset 1
Setting of the 5th decade
Setting Preset 2
Setting of the 6th decade
7.1 Setting of the sign
Select the sign by using the
flash now and can be assigned to the preset value or
eliminated by using the
seconds, the leading zero blanking will be activated
automatically again. Preset value and count value are
displayed now with the corresponding sign. Intent of
negative presets is to allow reset to a negative value.
Caution! In case of automatic resets no negative values
are to be set for preset 2.
Setting the sign for preset 1
key. The sign will start to
key. If no key is pressed for 4
MN05401005E