5. Setting of the operating parameters
a. connect to supply voltage
b. set DIP switch "A" (right side of the housing) to "ON"
for a short time. Display will show 1st menu item
"Mode".
c. select required function via
d. press P-key to store selected function/enter data and
to change over to next menu item.
e. select the desired function again via
data (prescaling factor, duration of timed signal, gate
time, resolution) directly via the two arrow-keys.
f.
After programming the last menu item (permanent or
timed signal), the programming routine will be exited
by pressing the P-key, if DIP switch "A" is set to
"OFF". If it is still set to "ON", the programming
routine will be passed through once again.
A B C D
OFF
ON
6. Setting of the operating mode
6.1 Selection of basic function
After DIP switch "A" has been switched to "ON" for a
short time, one of the basic functions will be displayed
as follows:
programming
programming
routine
routine
Impulse Counter
Timer
2
key
key to enter
programming
routine
Frequency Meter
6.2.1 Programming routine Impulse Counter
Operating mode Add:
Adding mode
Permanent signal at count value
Timed signal at count value
preset 1 and at count value
preset 2
Reset to zero
Operating mode Sub:
Subtracting mode
Permanent signal at count value
preset 1 and at count value
Timed signal at count value
preset 1 and at count value
Reset to preset 2
Operating mode AddAr:
Adding mode
Permanent signal at count value
preset 1 or timed signal at count
value = preset 1 and at count value
= preset 2
Automatic reset to zero
Operating mode SubAr:
Subtracting mode
Permanent signal at count value
preset 1 or timed signal at count
value = preset 1 and at count value
= zero
Automatic reset to preset 2
Operating mode AddbAt:
Adding mode
Timed signal at count value = preset
2 and automatic reset to zero.
A second adding preset counter
(batch counter), programmed preset
value = 1, counts the number of
auto matic repetitions of preset 2.
Permanent signal at count value
preset 1 or timed signal at count
value = preset value 1
The reset key sets both counters to
zero, the reset input only sets the
impulse counter to zero.
Operating mode SubbAt:
Subtracting mode
Timed signal at count value = zero
and automatic reset to preset 2.
Batch counter same as in mode
AddbAt.
The reset key sets the impulse
counter to preset 2 and the batch
counter to zero, the reset input only
sets the impulse counter to preset 2.
Polarity of the inputs:
pospol: positive polarity (PNP)
sourcing from +24V
negpol: negative polarity (NPN)
sinking to 0V
preset 1 and at count value
preset 2
MN05401005E
zero
zero