ABOUT THIS MANUAL
Because of the amount of models covered by this publication, the illustrations are typical ones. Some details of your unit may be slightly
different than the ones shown.
Please take note that this manual uses the following symbols to emphasize particular information:
Identifies an instruction which, if not followed, might cause serious personal injuries including possibility of death.
Identifies an instruction which, if not followed, may severely damage the unit and/or its components.
NOTE: Indicates supplementary information needed to fully complete an instruction.
ABOUT THESE UNITS
LIMITATION
For residential (domestic) installation only. Installation work and electrical wiring must be done by a qualified person(s) in accordance with
all applicable codes and standards, including fire-rated construction codes and standards.
WARNING
!
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSON(S) OBSERVE THE FOLLOWING:
. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or
1
telephone number listed in the warranty.
2. Before servicing or cleaning the unit, disconnect power cord from electrical outlet.
3. This unit is not designed to provide combustion and/or dilution air for fuel-burning appliances.
4. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
5. Do not use this unit with any solid-state speed control device other than following controls:
U
NIT
V
AVS S10 ERV
ENMAR
PLUS
V
AVS S10
ERV
ENMAR
N
PLUS
EE 70E+,
EE 70E
VÄN
VÄN
V
AVS S10 ERV, S10 ERV ECM
ENMAR
EE 70E, 70E ECM
VÄN
V
AVS S10
ERV
ENMAR
C
EE 70E
VÄN
C
6. This unit must be grounded. The power supply cord has a 3-prong grounding plug for your personal safety. It must be plugged into a
mating 3-prong grounding receptacle, grounded in accordance with the national electrical code and local codes and ordinances. Do
not remove the ground prong. Do not use an extension cord.
7. Do not install in a cooking area or connect directly to any appliances.
8. Do not use to exhaust hazardous or explosive materials and vapors.
9. When performing installation, servicing or cleaning these units, it is recommended to wear safety glasses and gloves.
10. When applicable local regulation comprise more restrictive installation and/or certification requirements, the aforementioned
requirements prevail on those of this document and the installer agrees to conform to these at his own expenses.
CAUTION
1. To avoid prematurate clogged filters, turn OFF the unit during construction or renovation.
2. Please read specification label on product for further information and requirements.
3. Be sure to duct air outside – Do not intake/exhaust air into spaces within walls or ceiling or into attics, crawl spaces, or garage.
4. Intended for residential installation only in accordance with the requirements of NFPA 90B (for a unit installed in U.S.A.) or Part 9 of the
National Building Code of Canada (for a unit installed in Canada).
5. Do not run any air ducts directly above or closer than 2 ft (0.61 m) to any furnace or its supply plenum, boiler, or other heat producing
appliance. If a duct has to be connected to the furnace return plenum, it must be connected not closer than 9' 10" (3 m) from this plenum
connection to the furnace.
6. The ductwork is intended to be installed in compliance with all local and national codes that are applicable.
7. When leaving the house for a long period of time (more than two weeks), a responsible person should regularly check if the unit
operates adequately.
8. If the ductwork passes through an unconditioned space (e.g.: attic), the unit must operate continuously except when performing
maintenance and/or repair. Also, the ambient temperature of the house should never drop below 18°C (65°F).
,
A
, D
LTITUDE
ECO
S
-T
IMPLE
OUCH
P
, D
LATINUM
ECO
+
N
S
-T
IMPLE
D
-T
, L
ECO
OUCH
ITE
D
-T
ECO
OUCH
L
-T
ITE
OUCH
L
-T
ITE
!
WARNING
CAUTION
M
C
AIN
ONTROL
-T
, L
-T
C
OUCH
ITE
OUCH
ONSTRUCTO
C
C
ONSTRUCTO OR
ONSTRUCTO
-T
, L
-T
B
,
OUCH
ITE
OUCH
RONZE
B
B
OUCH
RONZE OR
RONZE
-T
C
C
OUCH
ONSTRUCTO OR
ONSTRUCTO
, L
-T
B
B
ITE
OUCH
RONZE OR
RONZE
C
C
ONSTRUCTO OR
ONSTRUCTO
B
B
OUCH
RONZE OR
RONZE
2
A
UXILIARY
,
D
EHUMIDISTAT
20/40/60-
MINUTE LIGHTED PUSH
60-
AND
MINUTE CRANK TIMER
D
EHUMIDISTAT
20-
MINUTE LIGHTED PUSH
60-
AND
MINUTE CRANK TIMER
C
ONTROLS
,
-
BUTTON TIMER
,
-
BUTTON TIMER

Publicité

Chapitres

Table des Matières
loading

Table des Matières