Congratulations on buying an approved quality product meeting inter-
national standards. The sensor reliably alerts you in case of narcotic
gas attacks or gas leaks. The dynamic temprature compensation and
the continuous sensor self test ensure a reliable operation even under
different climatic conditions. In case of an gas alarm, the unit sends a
signal to the WiPro main unit which activates the siren and indicators
immediately. In Case of a gas alarm the WiPro will sound even in disar-
med state. When using solvents, cleaning agents or similar substances
near the Gas detector, switch off the gas detector to avoid unintended
activation of the alarm.
Wireless connection to main unit/range test:
Activate the learning mode as described in the WiPro resp. C.A.S.
installation manual and switch on the gas alarm by pushing Button A.
The WiPro main unit will acknowledge the reception by a single sound.
Repeat this procedure on the selected mounting place of the gas alarm
to make sure, the main unit is able to receive the signal.
Mounting locations:
Choose a location underneath the sleeping-places. Avoid vicinity to
heater outlets and lead-acid-batteries. The sensor is not to be used in
bathrooms. Before mounting carry out a range test. Switch on the unit
while WiPro is in diagnosis mode. If received the WiPro main unit will
confirm by a single sound.
Minimum seperations:
Heater outlets
Lead-acid-batteries
Installation:
• Mount the sensor to a wall or closet using the drilling template (Scetch
2) and the provided screws. Attention: screw in depth (scetch 1)!
• Plug the connection cable in the socket until it locks audible.
• You can lay the cable either through the wall or the small predetermi-
ned breaking point underneath the pushbutton (A).
Interconnections:
Connect the cable to an appropriate powersupply (12/24VDC)
brown
+ 12V/24V
white
GND (-)
green
not used