Control Panel - U.S. Products Solus 500 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CONTROL PANEL

A
HEAT CONTROL: This dial controls the water temperature. Turn it clockwise to increase water temperature and counterclockwise to decrease
temperature. The heater will operate only if the separate circuit locator light (E) or the bypass switch (F) is on.
B
HEAT MODE LIGHT: This light will only illuminate when the heater is heating and will turn off when it reaches operating temperature. During
normal operation, the "MODE" light will be on most of the time.
C
PUMP CONTROL: This dial controls motor speed and pump pressure. Adjust the dial clockwise to increase pressure and counterclockwise to
decrease pressure or turn off pump. The pump runs off of cord #1. The pump spraying pressure will be observable at the pressure gauge.
D
VACUUM SWITCH: This switch will illuminate when the vacuum motors are on. The vacuum motors run off of cord #1.
E
SEPARATE CIRCUIT LOCATOR LIGHT: When this light is on, it indicates that cord #2 (Identifi ed by the red "H" on the back of the extractor.)
is on a separate line from cord #1. Cord #2 supplies voltage to the heater allowing it to heat to the temperature range indicated by the Heat
Control dial (#1) on the switch plate.
F
BYPASS SWITCH: The bypass switch will illuminate when it is activated and will completely bypass the circuit locator system. Use this system
only when the circuit locator light will not turn on and you know each cord is on a separate circuit. NOTE: THE CIRCUIT BREAKER CAN TRIP
IF BOTH CORDS ARE ON THE SAME CIRCUIT AND THE BYPASS (heat) SWITCH IS TURNED ON.
A
6/07
B
D
INSTRUCTIONS FOR USE
E
56041969 - SOLUS
500
®
ENGLISH - A
C
F
7

Publicité

Table des Matières
loading

Table des Matières