TROUBLESHOOTING

IF THIS OCCURS
NO SPRAY
PUMP DOES NOT RUN
LOW SUCTION
NO SUCTION
LOW HEAT
NO HEAT
TECHNICAL SPECIFICATIONS (as installed and tested on the unit)
Model
Model No.
Roto-molded Body
Vacuum
VAC Shutoff
Pump
Waterlift
Heat
Heater
Wand
Weight
Dimensions
6/07
CHECK THIS
Solution tank is empty.
Clogged spray tip.
Pump not running or not primed.
Valve on wand not operating.
Check the brushes in the pump motor. Replace if necessary.
No power to pump. Test the Motor Speed Control Circuit Board and potentiometer.
Debris is plugging cleaning tool or vacuum hose.
Drain gate is not completely closed, or seals are damaged.
Vacuum lid is not seated or is damaged.
No power to motor.
Test the Electronic Float.
Test the switch.
Test the vacuum motor.
Test the Vacuum Circuit Board.
Check pre fi lter bag for debris.
Spraying too long. Try spraying for 12-15 seconds, or about three strokes.
Heat exchanger needs to be fl ushed.
Wrong tool being used. Too much water passing through. Longer hose or larger diameter hose, than
standard.
Heat is not turned on. Either the green light must be on or the bypass switch must be turned on.
No power in the wall outlet - check to see if the breaker has tripped.
No power to the bypass switch - check wiring for 'opens."
No power out of bypass switch, follow troubleshooting steps to isolate the problem.
CALL YOUR DISTRIBUTOR FOR ADDITIONAL HELP.
SOLUS-500 / SOLUS-500-S / SOLUS-500-DZ / SOLUS-500-B / 56380560
Positive displacement, fully adjustable 0-500 psi
Stainless steel, double bend, twin tip
INSTRUCTIONS FOR USE
Solus 500
Lifetime Warranty
Two 5.7", 3-stage
Electronic
100" -- 170 CFM
Adjustable to 212º F
2000 Watts
110 lbs.
24W x 28L x 41H (inches)
56041969 - SOLUS