ORDERING INFORMATION FOR MEGA ISLAND
MEGA island with
MULTIPOL IP65
MEGA ISLAND
Island versions
■ ■ ■ ■ ■ MULTIPOL IP65 :
One pressure inlet on
Island with
left-hand side
max. 10
With pressure inlet on
spool valves
left-hand and right-
hand side
One pressure inlet on
Island not
left-hand side
designed
With pressure inlet on
for future
left-hand and right-
extension
hand side
One pressure inlet on
Island
left-hand side
designed for
future
With pressure inlet on
extension
(2)
left-hand and right-
hand side
(max. 16 valves)
Port connections: 2 - 4
Instant fittings Ø8mm O.D.
Instant fittings Ø6mm O.D.
(1)
Mixed (E & S) on island
Auxiliary manual override
(▼) impulse
(●) locking (push-turn)
Mixed (1 & 2) on island
(1)
Pilots supply 12/14
Internal
External
Mixed (I & E) on island
(1)
Port connections: 1 - 3 / 5
Instant fittings 10 mm O.D.
G1/4
Option
without option
other options
Island mounting
Island delivery
On frame
Assembled
(2 x Ø4.2)
On rail
Assembled
EN 50022 - DIN
(1) Different spool valve versions can be mixed on an island. In this case:
- indicate type "P" in the basic reference
- fill in reference line
3
(2) Consult us for the max. number of spool valves in versions M5 and M6 with accessories D, X, Y, W, V
ORDERING EXAMPLE :
1
2
MEGA island, Multipol IP65, not designed for future extension, with SUB-D 37 connector. Unit supplied assembled, with end covers for
frame mounting and two pressure or vacuum inlets, left and right, G1/4 thread. 12 spool valves for connection with 8 mm OD instant
hose fittings, locking-type manual override, external pilot (versions not mixed).
Spool valve types:
- seven bistable 5/2 spool valves, type J, in positions 1 to 6 and 11
- two 5/3 spool valves, centre open to exhaust (W3), type E, in positions 7 and 8
- three monostable 5/2 spool valves, type M, in positions 9, 12 and 13
- one pressure separation plate, flow path 1 blocked, type W, in position 10
1
678
M
Type
M1
M2
M3
M4
M5
M6
Type
E
S
P
Type
1
2
P
Type
I
E
P
Type
Q
G
00
. .
99
Type
A
C
1
678M4E2EG00A
MMJWMEEJJJJJJ
2
Spool valve position
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
-
Please indicate the type of
spool valve or accessory required
Spool valves (functions)
2 x 3/2 NC-NC
5/2 - Solenoid air operated pilot, spring return (monostable) S
5/2 - Solenoid air operated pilot, differential return (monostable) M
5/2 - Solenoid air operated pilot and return (bistable)
5/3 - Pressure held (W1)
5/3 - Pressure applied (W2)
5/3 - Exhaust released (W3)
Reserve module (to be placed at the left end of the island)
Accessories
Intermediate pressure supply module
(connection is identical to that selected for ports 1 - 3/5
of end covers, see opposite)
Pressure separation plate (see page 9) :
• Total blocking of 1, 3 and 5 (no connection) ..................
• Blocking of 3 and 5 (port 1 connection maintained) ......
• Blocking of 1 (ports 3 and 5 connections maintained) ..
• No blocking (ports 1, 3 and 5 connections maintained)
(3) Mounting of module D requires a pressure separation plate to be written
in two positions (DX or XD see page 9)
3
Spool valve position
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
Spool valve versions (with mixed connections)
Port connections
Manual
2 - 4
override
(▼) impulse
Instant fittings
8 mm O.D.
(●) locking
(▼) impulse
Instant fittings
6 mm O.D.
(●) locking
How to fill in reference line
!
- Fill in only if different spool valve versions are to be
mixed on an island.
- Use the spool valve position numbers
specified in reference
- Repeat the type of accessory in the same position
number as specified in reference
MULTIPOL-IP65
Type
K
J
G
B
E
A
Type
(3)
D
X
Y
W
V
Pilots
Type
12/14
Internal
1
External
2
Internal
3
External
4
Internal
5
External
6
Internal
7
External
8
:
3
.
2
.
2
5