Technical Data - Polytropic R-PAC16 Manuel D'instructions

Masquer les pouces Voir aussi pour R-PAC16:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Polytropic

Technical data

Absorbed power
At 15° C ambiancy*
Heating Power
At 15° C ambiancy*
Heating Power
At 7° C ambiancy*
Heating Power
At -2° C ambiancy*
Water flow
Air flow
Noise level
(TUV ISO/EN 354)
Power supply
Dimensions
Weight
* water temperature 26° C (79° F)
At the end of product lifetime, this one must imperatively be entrusted to a qualified
professional (refrigeration technician) in order to dismantle it in accordance with the
laws in force (recovery of gas cooling, of metallic materials which can be recycled...).
R-PAC16
1,7 kW
8,1 kW
6,9 kW
4,6 kW
5 m³/h
2600 m³/h
57,5 dB à 1m
37,5 dB à 10m
230 V / 1~ / 50 Hz
1140 x 450 x 690 mm
73,0 kg
Conformity declaration
Conformity declaration
Conformity declaration
Conformity declaration
Polytropic pool heat pumps are standards to:
• Electromagnetic compatibility 89/336/CEE
• Tension low 73/23/CEE
R-PAC22
2,5 kW
12,2 kW
11,6 kW
8,7 kW
5 m³/h
2600 m³/h
59,6 dB à 1m
36,6 dB à 10m
78,5 kg
38
R-PAC31
3,8 kW
18,6 kW
16,8 kW
11,4 kW
7 m³/h
2 x 2600 m³/h
67,2 dB à 1m
47,2 dB à 10m
400 V / 3~ / 50 Hz
1140 x 450 x 1170
mm
117,0 kg

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

R-pac22R-pac31

Table des Matières