Timer; Emergency Operation For Wireless Remote-Controller - Mitsubishi Electric PKA-RP HAL Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28

4. Timer

4.1. For Wired Remote-controller
Timer functions are different by each remote controller.
For details on how to operate the remote controller, refer to the appropriate operation manual included with each remote controller.

5. Emergency Operation for Wireless Remote-controller

(For PKA-RP·HAL)
When the remote controller cannot be used
When the batteries of the remote controller run out or the remote control-
ler malfunctions, the emergency operation can be done using the emer-
gency buttons.
[Fig. 5-1] A DEFROST/STAND BY lamp
B Operation lamp
C Emergency operation switch (heating)
D Emergency operation switch (cooling)
E Receiver
10
Fig. 5-1
E.O.
SW
Fig. 5-2
Starting operation
• To operate the cooling mode, press the
seconds.
• To operate the heating mode, press the
seconds.
Stopping operation
• To stop operation, press the
than 2 seconds.
[Fig. 5-2] A DEFROST/STAND BY lamp (Orange)
B Operation lamp (Green)
C Emergency operation switch (cooling/heating)
D Receiver
• Each press of the emergency operation switch will toggle the operation
mode.
• Check "COOL/HEAT" with the operation monitor display. (The orange
lamp A follows this monitor display for 5 seconds after pressing the
emergency operation switch.)
[Heat pump type]
Cooling
Heating
Operation Monitor Display
GREEN ORANGE
STOP
COOL
HEAT
: Turning off
: Lighting
Note:
• Details of emergency mode are as shown below.
Operation mode
Set temperature
Fan speed
Airfl ow direction
Horizontal
button D for more than 2
button C for more than 2
button D or the
button C for more
[Cooling only type]
Stop
Cooling
Stop
The orange lamp follows the
switch operation as indicated at
the left for 5 seconds, and then it
will return to the normal display.
COOL
HEAT
24°C
24°C
High
High
Downward 4 (5)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pca-rp kaqPca-rp haq

Table des Matières