QuickTree® settings for PRO370 and PRO380 Systems:
When servicing the QuickTree
tighten the screw with a Philips screw driver do not over tighten. Flats have been formed on the rod to designate float positioning the
screw should be tightened onto the flat. The tether length is the amount of cord between the clamp and float.
TETHER LENGTH (SWITCH TO CLAMP)
ROD
POSITION Alarm Float Control Float Alarm Float Control Float
1
2
3
4
®
place the switch cord into the trough or channel then slip the stainless steel rod through the clamp and
©Copyright 2008 Liberty Pumps Inc. All rights reserved
P370
3.5"
3.5"
Float positions 1, 2, 3 and 4
are identified by a "flat"
stamped into the stainless
steel rod. 1 is highest, 4 is
lowest.
P370 and P380 systems have different tether
lengths. See above chart for proper tether length
and correct rod position.
P380
3.5"
3
.0"
6

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Pro380 serie