Télécharger Imprimer la page

Publicité

Liens rapides

Nemo D4-Dc
1
10782032
I
Cod. MF6DC
ISTRUMENTI MISURE ELETTRICHE SpA
Via Travaglia 7
20094 CORSICO (MI) ITALIA
Tel. +39 02 44 878.1
www.imeitaly.com
info@imeitaly.com
10/ 13
10782032

Publicité

loading

Sommaire des Matières pour IME Nemo D4-Dc

  • Page 1 Nemo D4-Dc 10782032 Cod. MF6DC ISTRUMENTI MISURE ELETTRICHE SpA Via Travaglia 7 20094 CORSICO (MI) ITALIA Tel. +39 02 44 878.1 www.imeitaly.com info@imeitaly.com 10/ 13 10782032...
  • Page 2 MF6DC4200H - MF6DC42006 INGRESSO / INPUT / ENTREE / EINGANG 10...300Vcc /dc S 1000/355 S 1000/356 O U T P U T O U T P U T I N P U T I N P U T ALARM PULSE RS 485 ALARM PULSE...
  • Page 3 ISTRUZIONI PER L’INSTALLAZIONE MOUNTING INSTRUCTIONS Prima di procedere alla installazione, verificare che i dati di targa (tensione, corrente, Before mounting, it is necessary to verify that data on the label (voltage, current, frequency) frequenza) corrispondano a quelli effettivi di rete. correspond to the real network ones.
  • Page 4 INSTRUCTIONS POUR L’ INSTALLATION INSTALLATION Avant de procéder à l’installation, il faut vérifier que les données indiquées sur la plaque Bevor das Gerät eingebaut wird, muss das Typenschild mit den tatsächlichen (tension, courant, fréquence) correspondent à celles du secteur. Netzgegebenheiten (Spannung, Strom, Frequenz) verglichen wird. PROGRAMMATION PROGRAMMIERUNG L’accès au menu de programmation est protégé...
  • Page 5 PROGRAMMAZIONE • PROGRAMMING • PROGRAMMATION • PROGRAMMIERUNG VISUALIZZAZIONE DISPLAY AFFICHAGE ANZEIGE PASSWORD PASSWORD MOT DE PASSE KENNWORT AZZERAMENTO PICCO POTENZA MEDIA RESET POWER MAX. DEMAND REMISE A ZERO PIC. PUISSANCE MOYENNE NULLSTELLUNG MITTLE LEISTUNGSSPITZE AZZERAMENTO CONTAORE RESETWORKING HOURS AND MINUTES REMISE A ZERO HEURES ET MINUTES DE FONCTIONNEMENT NULLSTELLUNGBETRIEBSSTUNDEN AZZERAMENTO AMPERE-ORA POSITIVI...
  • Page 6 PROGRAMMAZIONE • PROGRAMMING • PROGRAMMATION • PROGRAMMIERUNG Posizione cursore Position of the cursor TIME-OUT RS485 Position du curseur Cursorposition TIME-OUT RS485 3...100ms TIME-OUT RS485 Incrementa valore Increases the value ZEITSPERRE RS485 Augmente la valeur Es erhöht den Wert AL.1 GRANDEZZA ASSOCIATA ASSOCIATED QUANTITY GRANDEUR ASSOCIEE AUSGEWÄHLTE MESSGRÖßE...
  • Page 7 PROGRAMMAZIONE • PROGRAMMING • PROGRAMMATION • PROGRAMMIERUNG VISUALIZZAZIONE DISPLAY AFFICHAGE ANZEIGE Posizione cursore Position of the cursor PASSWORD Position du curseur Cursorposition PASSWORD MOT DE PASSE Incrementa valore Increases the value KENNWORT Augmente la valeur Es erhöht den Wert INGRESSO CORRENTE CURRENT INPUT Diretto (10A) Direct (10A)
  • Page 8 VISUALIZZAZIONE • DISPLAY • AFFICHAGE • ANZEIGE Tensione - Corrente - Potenza Voltage - Current - Power Tension – Courant - Puissance Spannung – Strom - Leistung Potenza media - Picco potenza media Power demand - Power max.demand Puissance moyenne – Pic de puissance moyenne Mittlere Leistung –...

Ce manuel est également adapté pour:

Mf6dc4200hMf6dc42006