Section 9 Operation - Samlexpower Pure Sine Wave PST-600-12 Guide Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

seCtIOn 9 |
optional Wired Remote control
An optional Wired Remote Control Model No. RC-15A (with 16.5 ft. / 5 metre cable), is
available for switching oN and switching off. The remote has LED indications similar
to the indications on the front panel (2,3,4 in fig. 61). Read Remote Control Manual for
details.
Powering on the Loads
After the inverter is switched on, it takes a finite time to become ready to deliver full
power. Hence, always switch on the load(s) after a few seconds of switching on the
inverter. Avoid switching on the inverter with the load already switched on. This may
prematurely trigger the overload protection.
When a load is switched on, it may require initial higher power surge to start. Hence, if
multiple loads are being powered, they should be switched on one by one so that the
inverter is not overloaded by the higher starting surge if all the loads are switched on at
once.
Switching the inverter on/oFF
Before switching on the inverter, check that all the AC loads have been switched off. The
oN/off switch (1) on the front panel of the inverter is used to switch on and switch off
the inverter. This switch operates a low power control circuitry, which in turn controls all
the high power circuitry. optional Remote Control Model RC-15A may also be used for
oN/off control.
!
cAUtion!
Please note that the oN/off switch is not switching the high power battery
input circuit. Parts of the DC side circuit will still be alive even when the switch
is in the off position. Hence, disconnect the DC and AC sides before working
on any circuits connected to the inverter.
When the inverter is switched oN, the GREEN "Power oN" LED (2, fig. 6.1) will be
lighted. This LED indicates that the input section of the inverter is operating normally.
Under normal operating conditions, AC output voltage will now be available at the GfCI
Duplex Receptacle (5). The Green indicator light on the GfCI will be lighted.
Switch on the AC load(s). The GREEN "Power oN" LED (2) and the indication light on
the GfCI should remain lighted for normal operation of the load.
temperature controlled cooling Fan
The cooling fan is thermostatically controlled. Temperature of a critical hot spot inside the
inverter is monitored to activate the fan and the over temperature shut-down. When the
temperature of this hot spot reaches 118.4°f / 48°C, the fan is switched oN. The fan will
36 | SAMLEX AMERICA INC.
Operation

Publicité

Chapitres

Table des Matières
loading

Table des Matières