seCtIOn 8 |
The corrosive fumes will corrode and damage the unit and if the gases are not venti-
lated and allowed to collect, they could ignite and cause an explosion.
Accessibility: Do not block access to the front panel. Also, allow enough room to access
the AC receptacles and DC wiring terminals and connections, as they will need to be
checked and tightened periodically.
Preventing Radio Frequency interference (RFi): The unit uses high power switching
circuits that generate RfI. This RfI is limited to the required standards. Locate any elec-
tronic equipment susceptible to radio frequency and electromagnetic interference as far
away from the inverter as possible. Read Section 3, page 11 "Limiting Electromagnetic
Interference (EMI)" for additional information.
overall Dimensions
The overall dimensions and the location of the mounting slots are shown in
fig. 8.1.1 and 8.1.2:
32
12
162
12
32
1,6
Fig. 8.1.1: PST-600 Overall Dimensions & Mounting Slots (NOTE: Dimensions in mm)
28 | SAMLEX AMERICA INC.
PST-600-dimensions
Installation
16,5
3,8
200
16,5
NEG –
NEG –
POS +
WARNING:
Reverse polarity will damage the unit.
AVERTISSEMENT :
Inversion de polarité peut endommager l'unité.
240.6
3,8
9,5
5
276,2
82