5.6
Replacing V-belt (Fig. 11)
Only for radial fans IMA 111 and IMA 185.
1.
Remove the cover (A).
2.
Lower the motor (B) by using the adjusting
nuts (C).
3.
Remove the old V-belt (D).
/i
Heater
V-belt tension
Pressure
IMA 111
4.4 lb
IMA 185
5.7 lb
Fit new V-belts in the reverse order.
Caution
Tighten the V-belt according to the table.
6.1
Troubleshooting table
/i
Fault
Cause
The heater does
1
The heater has no electric power. Check the power connection.
not start up.
2
The burner relay is in failure: the
light burns.
3
A malfunction has occured in the
burner relay.
4
The thermostat settings are
incorrect.
5
The room thermostat is defective. Replace the thermostat.
6
No cap is present on the
thermostat connection.
7
The fuel pump is blocked.
8
The maximum thermostat
stopped the heater.
9
The digital combination
thermostat or sensor is defective.
10
The main motor is overheated.
11
The capacitor of the burner motor
is defective.
12
The room thermostat has been
placed in the hot-air flow.
The burner starts,
13
The pump coupling is defective.
but no flame is
formed.
IMA-US
6
Distance
0.3 inch
0.35 inch
40.020.940 - rev. 04 - 2011

TROUBLESHOOTING

Before you trouble shoot, make sure
that the electricity is connected and the
fuel tank is full.
Warning
For all service and adjustments contact
qualified, competent and authorized
persons.
Warning
Disconnect the electric power during
repair!
Solution
Push the reset button of the
burner relay.
Replace the burner relay.
Correct the settings.
Place the cap if a room
thermostat is not used.
Replace the fuel pump.
Check (and correct) the airflow.
Reset the heater.
Replace the digital combination
thermostat or sensor.
Check the air inlet.
Let the motor cool down until the
reset of thermo couple.
See faults: 2, 3, 4, 5, 6, 8, 9.
Test the motor and replace if
necessary.
Replace the capacitor.
Install the room thermostat out of
this hot-air flow.
Replace the pump coupling.
English
Action
User
User
Dealer
Dealer
User
User
Dealer
User
Dealer
User
Dealer
Dealer
User
Dealer
11