Télécharger Imprimer la page

Greenheck SP110L Manuel D'installation, D'utilisation Et D'entretien page 2

Publicité

Les langues disponibles

Les langues disponibles

WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer at the address or telephone number
listed in the warranty.
2. Before servicing or cleaning unit, switch power off
at service panel and lock the service disconnecting
means to prevent power from being switched
on accidentally. When the service disconnecting
means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the
service panel.
3. Installation work and electrical wiring must be
done by a qualified person(s) in accordance with
all applicable codes and standards, including fire-
rated construction codes and standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of
fuel burning equipment to prevent backdrafting.
Follow the heating equipment manufacturer's
guideline and safety standards such as those
published by the National Fire Protection
Association (NFPA), and the American Society
for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the
outdoors.
7. Do not use this fan with any solid-state speed
control device.
8. Acceptable for use over a tub or shower when
connected to a GFCI (Ground Fault Circuit
Interrupter) - protected branch circuit.
9. This unit must be grounded.
2
SP Ceiling Exhaust Fans
For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
1. This product is designed for installation in ceilings
up to a 12/12 pitch (45 degree angle). Duct
connector must point up. DO NOT MOUNT THIS
PRODUCT IN A WALL.
2. To avoid motor bearing damage and noisy and/
or unbalanced impellers, keep drywall spray,
construction dust, etc. off power unit.
3. Please read specification label on product for
further information and requirements.
NOT FOR USE IN A COOKING AREA
Typical Installation
• Installation is the same for:
Joists
• Fits in 2" x 8" ceiling construction.
• Infinitely adjust the fan position between
joists from 14" to 24"
on center.
INSULATION*
(Place around and
over Fan Housing.)
FAN
HOUSING
POWER
CABLE*
Seal gaps
around
Housing.
ROUND
DUCT*
Seal duct
joints with
*Purchase
tape.
separately.
CAUTION
CAUTION
I-Joists
Trusses
OR
ROUND
ELBOWS*
ROOF CAP*
(with built-in
damper)
Keep duct
runs short.
WALL CAP*
(with built-in
damper)
®

Publicité

loading

Produits Connexes pour Greenheck SP110L

Ce manuel est également adapté pour:

Sp80l