Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

®
Installation, Operation and Maintenance Manual
Installation, Operation and Maintenance Manual
Please read and save these instructions for future reference. Read carefully before attempting to assemble,
Please read and save these instructions for future reference. Read carefully before attempting to assemble,
install, operate or maintain the product described. Protect yourself and others by observing all safety
install, operate or maintain the product described. Protect yourself and others by observing all safety
information. Failure to comply with instructions could result in personal injury and/or property damage!
information. Failure to comply with instructions could result in personal injury and/or property damage!
Model SP110L / SP80L
Service Parts
Greenheck
Key
Part No.
No.
1
435100
Mounting Frame
2
435101
Knockout Plate & Screws
3
435102
Housing
4
435103
Wiring Panel/Harness Assembly
434112
Control Assembly & Motor (SP80L)
5
435113
Control Assembly & Motor (SP110L)
6
435106
Duct Connector - 6"
7
435114
6" to 4" Reducer (model SP80L only)
8
435108
Blower Wheel
9
435115
Scroll Assembly
10
435117
Grille Assembly (includes 11, 12, 13)
11
435111
Grille Spring (2 req'd)
12
435118
Lens
13
435119
Bulb, GU24 18W 3500K FL (2 req'd)
Table of Contents
Warnings and Cautions ............................................ 2
Typical Installation .................................................... 2
New Construction Installation .................................. 3
Retrofit Installation ................................................... 7
®
Description
Easy installation in both new construction and retrofit.
6
7
Operation ................................................................ 11
Cleaning and Maintenance ..................................... 12
Troubleshooting ...................................................... 12
Our Commitment .................................................... 12
Document 99045144B
Model SP110L/SP80L
Lighted Multi-Speed
Ceiling Exhaust Fan
1
2
3
4
5
8
9
10
11
12
13
SP Ceiling Exhaust Fans
1

Publicité

loading

Sommaire des Matières pour Greenheck SP110L

  • Page 1 Knockout Plate & Screws 435102 Housing 435103 Wiring Panel/Harness Assembly 434112 Control Assembly & Motor (SP80L) 435113 Control Assembly & Motor (SP110L) 435106 Duct Connector - 6" 435114 6" to 4" Reducer (model SP80L only) 435108 Blower Wheel 435115 Scroll Assembly...
  • Page 2 WARNING CAUTION TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR For general ventilating use only. Do not use to exhaust INJURY TO PERSONS, OBSERVE THE FOLLOWING: hazardous or explosive materials and vapors. 1. Use this unit only in the manner intended by the 1.
  • Page 3 New Construction Installation Materials needed Tools needed • 6" round metal ducting recommended for best Power screwdriver with a Phillips bit performance. Use of other ducting is acceptable but Phillips screwdriver may impact performance. Flathead screwdriver • Roof cap or wall cap (built-in damper recommended) Pliers •...
  • Page 4 New Construction Installation 3 - Snap-in and Secure Housing Position Housing between joists and crimp channel on both sides of Mounting Frame Screws from Parts Bag to lock Housing in place. Do not crimp Housing. 4 - Attach Duct Connector and Ducting Top and bottom flanges Screw from go outside Housing...
  • Page 5 New Construction Installation 5 - Connect Wires and Install Knockout Plate • Run 120VAC electrical wiring to the installation location. • Use proper UL-approved connectors to secure wiring to the Knockout Plate provided in Parts Bag. • Connect wires as shown in wiring diagram. •...
  • Page 6 New Construction Installation 6 - Insert Mask and Finish Ceiling • Install ceiling material. • Cut out around Housing. Mask protects unit during construction. Remove before installing Grille. 7 - Install Grille 8 - Install Bulbs Night Light (purchase separately) NOTE: See Page 11 for Operations, Page 12 for Cleaning and Maintenance, and Troubleshooting.
  • Page 7 Retrofit Installation Materials needed Tools needed • Tape to seal duct connections Power screwdriver with a Phillips bit • Existing rigid duct will require the addition of a short Phillips screwdriver Ruler length of flexible duct Flathead screwdriver Pencil • Electrical wiring and supplies per local code Pliers Drywall saw requirements...
  • Page 8 Retrofit Installation 5 - Remove Blower Assembly Set aside Blower Assembly Both sides 6 - Remove Wiring Panel Set aside Wiring Panel Set aside screw 7 - Insert Mounting Frame Remove screws from Mounting Bend up Frame and set aside four tabs SP Ceiling Exhaust Fans ®...
  • Page 9 Retrofit Installation 8 - Secure Mounting Frame Screws set aside in Step 7 9 - Snap-in Housing Pull existing wiring into Housing as it is inserted into Mounting Frame 10 - Attach Ducting and Duct Connector Screw from Parts Bag Pull existing ductwork into Housing...
  • Page 10 Retrofit Installation 11 - Install Knockout Plate, (2) 2-FUNCTION Connect Wires and Install CONTROLS Wiring Panel MODE LIGHT SELECT • Use proper UL-approved connectors SWITCH NIGHT to secure wiring to the Knockout Plate LIGHT LIGHT provided in Parts Bag. MASTER NIGHT ON/OFF LIGHT...
  • Page 11 To Set the User-Adjustable Airflow Rate* Using a small, flat-blade screwdriver, carefully rotate the CFM adjustment until the arrow points to the desired airflow rate. SP110L User-adjustable controls SP Ceiling Exhaust Fans ®...
  • Page 12 For continuous ventilation, increase the “CFM” setting of the user-adjustable airflow rate. Our Commitment As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Specific Greenheck product warranties are located on greenheck.com within the product area tabs and in the Library under Warranties.
  • Page 13 Pour votre protection et celle des autres, respectez toutes les informations de sécurité. Toute infraction à ces instructions peut provoquer des blessures corporelles et des dommages matériels! Installation facile aussi bien dans les constructions Modèle SP110L / SP80L neuves que les rénovations. Pièces de rechange Greenheck N°...
  • Page 14 AVERTISSEMENT ATTENTION À utiliser pour la ventilation générale uniquement. Ne POUR RÉDUIRE LE RISQUE D’INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURE CORPORELLE, RESPECTER pas utiliser pour l’aspiration de matières et vapeurs CE QUI SUIT : dangereuses ou explosives. 1. Utiliser cet appareil exclusivement comme prévu par 1.
  • Page 15 Installation dans une construction neuve Matériels nécessaire Outillage nécessaire • Gaine métallique ronde de 6 po conseillée pour un Visseuse électrique à embout Phillips fonctionnement optimal. L’utilisation d’autres gaines Tournevis Phillips est acceptable mais peut altérer les performances. Tournevis plat • Chapeau de toiture ou chapeau mural (registre Pince intégré...
  • Page 16 Installation dans une construction neuve 3 - Enclencher et fixer le caisson Placer le caisson entre les solives et pincer le profilé des deux côtés du bâti de montage pour bloquer le caisson en place. Ne pas pincer le caisson. Vis du sachet de pièces 4 - Attacher le connecteur de gaine et la gaine Placer les brides supérieure...
  • Page 17 Installation dans une construction neuve 5 - Raccorder les câbles et poser la plaquette défonçable • Tirer un câble d’alimentation 120 Vc.a. jusqu’à l’emplacement de l’installation. • Utiliser des connecteurs homologués UL qui conviennent pour attacher le câble à la plaquette défonçable fournie dans le sachet de pièces.
  • Page 18 Installation dans une construction neuve 6 - Insérer le masque et finir le plafond • Poser le matériau de plafond. • Découper sur le pourtour du caisson. Le masque protège l’appareil durant la construction. L’enlever avant de poser la grille. 7 - Poser la grille 8 - Poser les ampoules Veilleuse (acheter...
  • Page 19 Installation de rénovation Matériels nécessaire Outillage nécessaire • Ruban d’étanchéité pour les raccordements de gaine Visseuse électrique à embout Phillips • La gaine rigide existante nécessitera l’ajout d’un Tournevis Phillips Règle courte longueur de gaine flexible Tournevis plat Crayon • Câblages et fournitures électriques conformes au Pince Scie pour cloison sèche code de l’électricité...
  • Page 20 Installation de rénovation 5 - Déposer la soufflante Conserver la soufflante Des deux côtés 6 - Déposer le panneau de câblage Conserver le panneau de câblage Conserver la vis 7 - Insérer le bâti de montage Déposer les vis du bâti de montage et Plier les quatre pattes les conserver...
  • Page 21 Installation de rénovation 8 - Fixer le bâti de montage Vis conservées à l’étape 7 9 - Enclencher le caisson Tirer le câblage existant dans le caisson lorsqu’il est inséré dans le bâti de montage 10 - Attacher la gaine et le connecteur de gaine Vis du sachet de pièces Tirer la gaine...
  • Page 22 Installation de rénovation 11 - Poser la plaquette (2) COMMANDES défonçable, raccorder les 2 FONCTIONS câbles et poser le panneau SÉLECTEUR LAMPE de câblage DE MODE LAMPE • Utiliser des connecteurs homologués VEILLEUSE INTERRUPTEUR UL qui conviennent pour attacher GÉNÉRAL M/A VEILLEUSE le câble à...
  • Page 23 (en pieds-cubes par minute). Régler la temporisation ajustable par l’utilisateur* Avec un petit tournevis plat, tourner avec précaution Commandes ajustables par l’utilisateur SP110L le réglage de temporisation (TIME) pour faire pointer la flèche sur la valeur souhaitée (en minutes).
  • Page 24 (CFM). Notre engagement Dans le cadre de son engagement à l'amélioration continue de ses produits, Greenheck se réserve le droit de modifier leurs caractéristiques sans préavis. Les garanties sur les produits Greenheck particuliers se trouvent à greenheck.com, sous les onglets des produits et dans la bibliothèque (Library), sous Warranties.

Ce manuel est également adapté pour:

Sp80l