Replacing Nozzles
The burners can be adapted to suit different
types of gas by fitting the nozzles that corres-
pond to the gas used. To do this, it is
necessary to remove the burner heads and
use a straight key "B" to unscrew the nozzle
"A" (see Fig. 7) and replace it with a nozzle
corresponding to the gas used.
Be sure the nozzle is seated tightly.
After making these replacements, the technician must regulate the
burners as described in Adjustments on the previous page and reset
any seals. He should affix the label corresponding to the new gas type
to replace the label previously applied. The nozzles and labels may be
included in a kit with the unit, or obtained from the dealer.
How to change the setting of the pressure regulator supplied with the
cooktop:
The gas regulator was set up to Natural Gas. To convert to LP Gas:
1. Unscrew the aluminum cap
2. Remove and turn the plastic pin 180°
3. Screw in the plastic pin
4. Screw in the aluminum cap
To make it easier for the fitter, we have prepared a table indicating the flow
capacities, the heat capacities of the burners, the diameter of the nozzles and
the working pressure for the various types of gas.
Burners
No.
Description
1
Ultra-Rapid
3
Semi-Rapid
1
3
Normal
Manifold
Gas
Pressure,
inches water
column
Propane HD-5
Natural Gas
Propane HD-5
Natural Gas
3
1
Injector
Diameter,
1/100 mm
11
94
4
170
11
70
4
120
10
Fig. 7
Arrangement
of Burners
Nominal Heat
Input (Btu/h)
Min.
Max.
5100
11000
5100
12000
2400
6000
2400
6000