Always disconnect the appliance from the electrical power source
before making any adjustments. All seals must be replaced by the
technician when any adjustments are completed.
The burners do not require any regulation of incoming air.
Taps
"Reduced rate" adjustment:
1. Switch on the burner and turn the relative knob to the "Reduced rate"
position (small flame fig. 8 page 11).
2. Remove knob "M" (fig. 6 and 6/A) of the tap, which is simply pressed on to
its rod.
3. The by-pass for minimal rate regulation can be: beside the tap (fig. 6) or
inside the shaft. In any case, to access the regulation, it can be done
through the insertion of a small screwdriver ''D'' beside the tap (fig. 6) or in
the hole ''C'' inside the shaft of the tap (fig 6/A).
Turn the throttle screw to the right or left until the burner flame has been
adequately regulated to the "Reduced rate" position.
The flame should not be too low: the lowest small flame should be continuous
and steady. Re-assemble the several components.
It is understood that only burners operating with Natural Gas or City Gas
should be subjected to the above-mentioned adjustments. The screw
must be fully locked when the burners operate with Propane (turn
clockwise).