INSTALLATION
5-1/2"
[14 cm]
1-3/4"
[4.4 cm]
Two WM2L Dual Blowers (1200 CFM)
4. Remove the hood from its packaging and place the back of the hood on the floor or countertop
in front of the wall where it will hang.
5. With the hood on its back facing you, remove
the shield(s) and blower housing(s) as follows:
a) Remove the shipping tape that is securing
the blower shield(s) inside the hood.
b) Remove the blower shield(s) by lightly
pulling it toward the front of the hood.
c) Gently close the back draft damper(s) from
the top side of the hood.
d) To remove the blower housing(s), unsnap
the suitcase latches (one on each side of
the housing).
e) Support the housing and lift it away from the blower base, then tip it back toward you to
clear the blower wheel(s), and then pull it from the hood.
6. One blower motor must be removed from each blower assembly to access the connection
box(es). The blower assembly will have a decal identifying the location of the connection
box(es). It is not necessary to remove the blower wheel from the motor.
a) Remove the three screws retaining the blower motor.
b) Pull the motor out far enough so you can reach its electrical connector.
c) Unplug the connector, set the blower motor and screws aside.
7. WIRING PREPARATION:
a) Install an appropriate 1/2" UL listed electrical wire clamp through each motor box
electrical opening on top of the hood.
b) Install electrical wiring from the service panel to the hood location for each motor box.
Consult the connection diagrams (on previous page) for further details on electrical
placement. See "ELECTRICAL SUPPLY AND GROUNDING" on page 1 for power
requirements.
(CONT.)
Connection diagram (54" width)
11"
[29.9 cm]
5-1/4"
[13.3 cm]
8" [20.3 cm]
Round
[45.7 cm]
Make sure power is off at the supply panel / breaker during service or
installation.
11"
[29.9 cm]
Electrical (2)
Centerline
of Hood
(Top View)
[30.5 cm]
7-1/2"
[19.1 cm]
18"
Optional AKVT8812
transition piece installed
©2020 Hestan Commercial Corporation
(Wall Side)
Motor
Cooling
Vent (4)
8" [20.3 cm]
Round
12"
(Front View)
13
EN