FINAL INSTALLATION
PROPER AIR CIRCULATION (Except KRP)
PROPER AIR CIRCULATION (Except KRP)
A forced air system assures ventilation through a grille positioned in the
lower front of the unit. If the kitchen design includes an applied toekick, it
must have ample openings/slots to maintain proper airflow as illustrated
below. Holes/slots can be of any size and shape, provided that the total open
area amounts to 50% of the overall size of the decorative cover.
In this case, to guarantee proper airflow, it is recommended to remove the
front grille included with the unit. The provided grille is secured to the unit
with magnetic plates and can be easily removed. The cover should be
removed for regular cleaning and removal of dust. If a decorative
grille is used, remove the provided grille to allow for proper airflow.
The chart and illustration below provides the proper amount of
airflow necessary to maintain. (All models except KRP.)
36" Models
33-7/8 " [860 mm]
A
B
C
B
(CONT.)
30" Models
24" Models
29-1/8 " [740 mm]
22" [560 mm]
> 4" [100 mm]
3/8" [10 mm]
A
18" Models
16-1/8" [410 mm]
C
C
© 2021 Hestan Commercial Corporation